Temperature Alarms and Transmitters |
|||
---|---|---|---|
Product brochure Options & accessories Regulatory compliance Click on PDF links below for product information |
Reference Info Sink or Source LoopTracker and Output Test Signal Conditioner Terminology Industry Terminology RFI & EMI Ohm's Law What is a Ground Loop? Applications Dam Bubbler Chiller Temperature Bearing Temperature Motor Temperature Motor Overheating |
How to select your product
|
Ready to order? Other ways to order
|
Model | Input/Output | Features | Product |
Universal Input to DC Isolated Signal ConditionerField ProgrammableAPD 8000 from $529*Free I/O Range Setup* Include your I/O ranges on your order, and we'll set it up for you! Open Datasheet Download Datasheet Open Feature Summary Download Feature Summary |
Field configurable inputs DC volts: 35 ranges from ±25mVDC to ±10 VDC DC mA sinking input, 20 ranges from ±0.5mADC to ±20mADC Potentiometer: 100Ω min. to 1 MegaΩ max. Thermocouple: J, K, T, E, R, S, N, B, C, D, G, M, P RTDs: 2, 3, or 4 wire, 10Ω to 8000Ω RTDs Thermistor: 44000 series, YSI 400, Spectrum Custom input available 18 field programmable output ranges Voltage: 0-1V, 0-2V, 0-4V, 0-5V, 1-5V, 0-8V, 0-10V, 2-10V, ±5V, ±10V Current: 0-2mA, 0-4mA, 0-8mA, 0-10mA, 2-10mA, 0-16mA, 0-20mA, 4-20mA Can be wired for sink or source |
|
APD 8000 |
Thermocouple to DC Isolated Signal ConditionerFactory Configured APD 4131 from $469Open Datasheet Download Datasheet |
Specify T/C type and °F or °C temperature range Factory configured Thermocouples J, K, T, E, R, S, N, B, C, D, G, M, P ±0.25°C Accuracy Microprocessor-based linearization Specify output range Factory configured analog output 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 4131 |
Thermocouple to DC Isolated Signal ConditionerFactory Configured API 4130 GL from $439Open Datasheet Download Datasheet Open Feature Summary Download Feature Summary API 4130 GL sold before 07-12-16Open Datasheet Download Datasheet |
Specify T/C type and °F or °C temperature range Factory configured Thermocouples J, K, T, E, R, S, N, B, C, D, G, M, P ±0.25°C Accuracy New microprocessor-based linearization Specify output range Factory configured analog output 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
API 4130 GL |
Thermocouple to Dual Thermocouple Splitter/ConverterFactory Configured APD 41390 from $599Open Datasheet Download Datasheet |
Specify T/C input type and range T/C: J, K, T, E, R, S, N, B, C, D, G, M, P Temperature range may be limited by the smallest ANSI range of the 3 T/C types you select Upscale burnout (std), downscale burnout or last known value Specify output types and ranges Channel 1 Thermocouple output type Channel 2 Thermocouple output type Alarm options Hi, Lo, latching, failsafe, reverse |
|
APD 41390 |
Thermocouple to DC and Thermocouple Splitter/ConverterFactory Configured APD 41391 from $599Open Datasheet Download Datasheet |
Specify T/C input type and range T/C: J, K, T, E, R, S, N, B, C, D, G, M, P Temperature range may be limited by the smallest ANSI range of the 2 T/C types you select Upscale burnout (std), downscale burnout or last known value Specify output types and ranges Channel 1 Process DC output: V or mA Sink/source mA output Channel 2 Thermocouple output type Alarm options Hi, Lo, latching, failsafe, reverse |
|
APD 41391 |
Thermocouple to Dual DC Splitter/TransmitterFactory Configured APD 41393 from $599Open Datasheet Download Datasheet |
Specify T/C input type and range T/C: J, K, T, E, R, S, N, B, C, D, G, M, P Specify DC output types and ranges Channel 1 Process DC output: V or mA Sink/source mA output Channel 2 Process DC output: V or mA Sink/source mA output Alarm options Hi, Lo, latching, failsafe, reverse |
|
APD 41393 |
Thermocouple Input Single Alarm TripFactory configured API 1200 G from $319Open Datasheet Download Datasheet |
API 1200 G Single DPDT Alarm Trip
|
|
API 1200 G |
Thermocouple Input Dual Alarm TripFactory configured API 1220 G from $339Open Datasheet Download Datasheet |
API 1220 G Dual SPDT Alarm Trip
|
|
API 1220 G |
Thermocouple Input Alarm TripsFactory Configured APD 1200 from $379 |
Specify T/C type and °F or °C temperature range Factory configured Thermocouple J, K, T, E, R, S, N, B, C, D, G, M, P 100°F (55°C) recommended minimum span APD 1200 Single Alarm Trip Dual DPST contact set Standard: HI alarm, normal acting, set/reset adjustments, non-latching APD 1220 Dual Alarm Trip Two DPST contact sets Standard: HI/LO alarms, normal acting, two set/reset adjustments, non-latching |
|
APD 1200, APD 1220 |
RTD Input Alarm TripsFactory Configured API 1400 G from $309 |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω: 0.00385α, 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or special API 1400 G Single Alarm Trip One DPDT contact set, adjustable deadband Standard: HI alarm Optional: LO alarm API 1420 G Dual Alarm Trip Two SPDT contact sets, 1% deadband Standard: HI/LO alarms, normal acting Optional: LO/HI, HI/HI, LO/LO alarms |
|
API 1400 G, API 1420 G |
RTD Input Alarm TripsFactory Configured APD 1400 from $369 |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω: 0.00385α, 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special APD 1400 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1420 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options |
|
APD 1400, APD 1420 |
RTD or Thermistor Input Alarm TripsFactory Configured APD 1401 from $379 |
RTD: specify type, 2, 3 or 4 wire, and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω: 0.00385α, 0.003916α, 0.00392α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special Thermistor: specify type and temperature range. For other sensor types provide temperature-resistance chart. Factory configured 44004/44033 2.252 kΩ at 25°C 44005/44030 3.000 kΩ at 25°C 44007/44034 5.000 kΩ at 25°C 44006/44031 10.00 kΩ at 25°C 44008/44032 30.00 kΩ at 25°C YSI 400 2.252 kΩ at 25°C Spectrum 1003k 1 kΩ APD 1401 Single Alarm Trip Dual DPST contact sets Standard: HI alarm, non-latching, normal acting APD 1421 Dual Alarm Trip Two DPST contact sets Standard: HI/LO alarms, normal acting, two set/reset adjustments, non-latching See data sheet for alarm options |
|
APD 1401, APD 1421 |
RTD to DC Isolated TransmitterFactory Configured APD 4001 from $449Open Datasheet Download Datasheet |
Specify RTD type and temperature range 10 Ω to 2000 Ω RTD including 100 Ω: 0.00385α, 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or special Specify output range 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 4001 |
RTD to DC Isolated TransmitterFactory Configured API 4001 G L from $449Open Datasheet Download Datasheet |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω: 0.00385α, 0.00391α 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or special Specify output range Factory configured 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
API 4001 GL |
Universal Input to 4-20 mA |
Field Programmable Input Requires EASY-USB for configuration Input: –150 mV to +150 mV –30 V to +30V –24 mA to 24 mA RTD: Pt100, Pt500, Pt1000, Ni100 Thermocouple: J, K, T, E, R, S, B, N Potentiometer: 500 Ω to 10 KΩ Resistance: 1750 Ω Output: 4-20 mA loop powered Powered by the output loop |
|
K121 |
Thermocouple to DC Isolated TransmitterField ConfigurableK109TC $250 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
Field Configurable Input Input: Thermocouple: J, K, T, E, R, S, N, B Field Configurable Output Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA, 0-5 V, 1-5 V, 0-10 V, 10-0 V |
|
K109TC |
100 Ω RTD to DC Isolated TransmitterField ConfigurableK109PT $250 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
Field Configurable Input Input: One 100 Ω RTD, 385 Curve RTD, 2, 3, or 4 wire –150 to 650°C, (–238 to 1202°F), 50°C min. span Field Configurable Output Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA, 0-5 V, 1-5 V, 0-10 V, 10-0 V |
|
K109PT |
IsoSplitter® Signal Splitter |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu 1000 Ω Ni-Fe 120 Ω Ni or special Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 1393 |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series from $609 |
Specify input range for each channel APD 2001 Ch1: DC mV/V/mA Ch2: RTD APD 2011 Ch1: RTD Ch2: RTD APD 2013 Ch1: RTD Ch2: Potentiometer APD 2015 Ch1: RTD Ch2: Strain gauge APD 2016 Ch1: RTD Ch2: AC mV/V/mA APD 2017 Ch1: RTD Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series RTD |
RTD to DC Isolator/Converter |
Input One RTD Selectable for Pt100, Pt500, Pt1000, Ni100 2/3/4 wire Configurable range Output One isolated mA or Voltage Sink or source mA Configurable range |
|
Z109PT2-1 |
Universal Input to DC Isolator/Converter |
Configurable Input mV, V, (Bipolar from 75 mV to 20 V) mA (Bipolar up to 20 mA) RTD: Pt100, Pt500, Pt1000, Ni100, KTY81, KTY84, NTC; 3-4 wire Thermocouple: Type J, K, R, S, T, E, B, N, Potentiometer: 500 Ω to 100 kΩ Rheostat: 500 Ω to 25 kΩ Strobe: Alternative to output relay Output One isolated mA or Voltage Sink or source mA Configurable range 1 relay output |
|
Z109REG2-1 |
ThermoPro® |
T16BBL: Backlit display
|
|
T16B |
ThermoPro® |
|
|
T16L |
ThermoPro® |
|
|
T16ADA |
Head-Mount RTD Transmitter, Non-IsolatedField ProgrammableFits DIN Form B Heads T120 $89 *stock item*T120-C $109 pre-programmed to orderOpen Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
Programmable Requires EASY-USB for configuration Input: Pt100 or Ni100 RTD 2, 3, or 4 wire Selectable Output Output: 4-20 mA, 20-4 mA |
|
T120 |
Head-Mount Universal Transmitter, IsolatedField ProgrammableFits DIN Form B Heads T121 $159 *stock item*T121-C $179 pre-programmed to orderOpen Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
Programmable Requires EASY-USB for configuration Input: Pt100 or Ni100, Pt500, Pt1000 J, K, R, S, T, B, E, N Potentiometer mVDC, VDC Selectable Output Output: 4-20 mA, 20-4 mA |
|
T121 |
USB - UART TTL ConverterEASY-USB $140 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual EASY-USB Software Link |
Programming Kit for K121, T120, T121 |
Includes Converter Software mini CD (or download latest) Adapter cable (std USB cable not included) |
EASY-USB |
4 Digit 4-20 mA Loop Powered DisplayField RangeableS315 $150 *stock item* |
Loop Powered Display Input: 4-20 mA Display: 4 digit red LED |
|
S315 |
Analog To Resistance ConverterFactory Configured ATR167 call for quoteOpen Datasheet Download Datasheet |
Specify input type and range RTD Thermocouple Frequency to 5kHz Pulse input from proximity sensor Millivolt/Volts Potentiometer or resistance Specify output range Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom |
|
ATR167 |
Analog To Potentiometer ConverterFactory Configured ATP 168 call for quoteOpen Datasheet Download Datasheet |
Specify input type and range RTD Thermocouple Frequency to 5kHz Pulse input from proximity sensor Millivolt/Volts Potentiometer or resistance Specify output range Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom |
|
ATP168 |