AC Input Alarms, Signal Conditioners, Converters, Isolators, Transmitters

lifetime warranty
  • Lifetime Warranty on API Modules
  • LoopTracker® I/O LEDs
  • Hot-Swappable Plug-In Design
  • Zero and Span Output Calibration
  • Push to Test Output
  • Full I/O/Power Isolation



Click on model numbers below
for data sheets
Literature and Links

API product brochure

Options & accessories

Cross reference

UL Approvals

API modules USA
API modules Canada

APD modules USA
APD modules Canada

Transmitter Reference Info

Ground Loops
RFI/EMI
LoopTracker and Output Test
Sink vs Source

Alarm Reference Info

Alarm Terminology
Deadband
Relay Protection & EMI Suppression
RFI / EMI
Installation FAQ
Motor Load Current

Applications

Monitor & display AC motor load
Monitor computer & process status
Monitor motor speed using current
Aircraft deicing
Heater Break Alarm
Monitor Mold Heaters
Railroad Crossing Current Monitor
How to Order
  1. Select a model
  2. See data sheet for ordering info and power options
  3. Request an API price list via chat
  4. 2 day to 4 week typical lead time (USA customers)
  5. To place your order
Model Input/Output Features Product
AC to DC Signal Conditioners
Plug In Style

API 6010 G
Specify input range
Factory configured
0-50 mVAC to 0-300 VAC
0-1 mAAC to 0-900 mAAC
5A shunt option: 0-900 mAAC to 0-5 AAC

Specify output range
Factory configured
0-1 V to 0-10 V
±1 V to ±10 V
0-1 mA to 0-20 mA, 4-20 mA
  • RepalcesAction AP 6010
  • I/O LoopTracker LEDs
  • Full I/O/power isolation
  • Output test button
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 85-265 VAC, 60-300 VDC power
  • D option for 9-30 VDC power


Api 6010G UL listed
API 6010 G
AC to DC Signal Conditioners
Factory configured
DIN Style

APD 6010
Specify input range
True RMS
0-50 mVAC to 0-300 VAC
0-1 mAAC to 0-1000 mAAC

Specify output range
0-1 V to 0-10 V
±1 V, ±10 V
0-1 mA to 0-20 mA, 4-20 mA
  • I/O LoopTracker LEDs
  • Full I/O/power isolation
  • Output test button
  • Mount to 35 mm DIN rail
  • True RMS input measurement
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power


APD 6010UL approved
APD 6010
AC to DC Signal Conditioners
Field Selectable Minuteman Setup
DIN Style

APD 6380
Hundreds of input ranges
True RMS
0-40 mVAC to 0-300 VAC
0-4 mAAC to 0-200 mAAC
APD 6380 ranges

18 output ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA, 4-20 mA
  • Hundreds of I/O range combinations
  • True RMS for distorted waveforms
  • Removable plugs
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Selectable sink/source mA output
  • 20 V output loop power supply
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power

APD 6380UL approved
APD 6380
AC to DC Signal Conditioners
Plug In Style
Field Selectable Minuteman Setup

API 6380 G
API 6380 G S

20 input ranges
Order S version for true RMS
0-5 mAAC to 0-200 mAAC

16 output ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA, 4-20 mA
  • S version is true RMS for distorted waveforms
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 85-265 VAC, 60-300 VDC power
  • D option for 9-30 VDC power



Api 6380 G UL listed
API 6380 G, API 6380 G S
AC to DC Signal Conditioners
High Voltage Input Ranges
Plug In Style
Field Selectable Minuteman Setup

API 6380 G HV
API 6380 G S HV


24 input ranges
Order S version for true RMS
0-50 mVAC to 0-600 VAC
0-5 mAAC to 0-200 mAAC
Like API 6380 G but with additional input ranges
0-300VAC, 0-400VAC, 0-500VAC, 0-600VAC

16 output ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA, 4-20 mA
  • S version is true RMS for distorted waveforms
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 85-265 VAC, 60-300 VDC power
  • D option for 9-30 VDC power



Api 6380 G HV UL listed
API 6380 G HV, API 6380 G S HV
IsoSplitter® AC Signal Splitters
One AC Signal Input to Two DC Outputs

Factory configured
DIN Style

APD 6393

Specify mVAC, VAC or mAAC input range
True RMS
0-50 mVAC to 0-300 VAC
0-1 mAAC to 0-1000 mAAC
Input frequency: 40 Hz to 1000 Hz sinusoidal

Specify output range for each channel
2 independent output channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
  • One AC input
  • Two isolated DC output channels
  • I/O LoopTracker LEDs
  • Selectable sink/source mA output
  • 20 V output loop power supply
  • Output test buttons
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount
  • 45 mm wide
  • Universal power 85-265 VAC, 60-300 VDC
  • D for 9-30 VDC, 10-32 VAC power

AC input IsoSplitterUL approved
APD 6393 AC IsoSplitter
DuoPak®
Two Channel Signal Conditioners

DIN Style

APD 2000 Series
Specify input range for each channel
Factory configured
APD 2016 Ch1: RTD Ch2: AC mV/V/mA
APD 2036 Ch1: Potentiometer Ch2: AC mV/V/mA
APD 2056 Ch1: Strain gauge Ch2: AC mV/V/mA
APD 2066 Ch1: AC mV/V/mA Ch2: AC mV/V/mA
APD 2067 Ch1: AC mV/V/mA Ch2: Frequency

Specify output range for each channel
2 independent channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA




  • Optional I/O reversal
  • Selectable sink/source mA output
  • 20 V output loop power supplies
  • I/O LoopTracker LEDs
  • Output test buttons
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount
  • 45 mm wide
  • Universal power 85-265 VAC, 60-300 VDC
  • D for 9-30 VDC, 10-32 VAC power

DuoPakUL approved
APD 2000 Series AC
AC Input Alarm Trips
Plug In Style

API 1600 G
API 1620 G

Specify input range
Factory configured
0-50 mVAC to 0-300 VAC
0-1 mAAC to 0-900 mAAC
5A shunt option: 0-900 mAAC to 0-5 AAC

API 1600 G Alarm Trips
One DPDT contact set
Standard: HI alarm, normal acting,
adj. deadband, non-latching
See data sheet for alarm options

API 1620 G Dual Alarm Trip
Two SPDT contact sets
Standard: HI/LO alarms, normal acting,
1% deadband, non-latching
See data sheet for alarm options
  • User adjustable setpoint(s)
  • 8 Amp contacts
  • Hot-swappable plug-in design
  • RepalcesAction AP 1600 and AP 1620
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm options: LO, HI/HI, LO/LO
  • Optional reverse acting
  • Optional latching alarms
  • Output test button
  • Uses API-011 or API-011FS 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 85-265 VAC, 60-300 VDC power
  • D option for 9-30 VDC power


Api 1600 G
API 1600 G, API 1620 G
AC Input Alarm Trips
DIN Style

APD 1600
APD 1620

Specify input range
Factory configured
0-50 mVAC to 0-300 VAC
0-1 mAAC to 0-1000 mAAC

APD 1600 Single Alarm Trip
Dual SPDT contact sets
Standard: HI alarm, non-latching,
normal acting
See data sheet for alarm options

APD 1620 Dual Alarm Trip
2 independent SPDT contact sets
Standard: HI/LO alarms, non-latching,
normal acting
See data sheet for alarm options

  • Measurements are true RMS
  • User adjustable setpoint(s)
  • User adjustable deadband(s)
  • 8 Amp SPDT contacts
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm options: LO, HI/HI, LO/LO
  • Optional reverse acting
  • Optional latching alarms
  • Push to test/reset
  • Remote push to test/reset
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount without tools
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power


APD 1600UL approved
APD 1600, APD 1620
AC Current Switches

CS-AC-1
CS-AC-2

Input
0-150 Amps AC input

Output
CS-AC-1: NC solid state relay, 0.15A@130VAC/VDC
CS-AC-2: NO solid state relay, 0.15A@240VAC/VDC
  • Adjustable 1.5 to 150 Amp setpoint
  • Self-powered
  • Split core design
  • LED status indicator
  • 5-year warranty
  • 2 day to 4 wk lead time

CE UL
apicsac
CS-AC Series



S315 and S315-IP66
4 Digit 4-20 mA Loop Powered Display

1/8 DIN

S315 and S315-IP66 datasheet

S315 and S315-IP66 installation
Loop Powered Display
Input: 4-20 mA
Display: 4 digit red LED

  • 1/8 DIN panel mount or IP66 housing
  • Scalable 4 digit display

CE logo  new!
S315
S315