AC Input Alarms, Signal Conditioners, Converters, Isolators, Transmitters |
|||
---|---|---|---|
Product brochure Options & accessories Cross reference Regulatory compliance Click on PDF links below for product information |
Transmitter Reference Info Ground Loops RFI/EMI LoopTracker and Output Test Sink vs Source Alarm Reference Info Alarm Terminology Deadband Relay Protection & EMI Suppression RFI / EMI Motor Load Current Applications Heater Break Alarm Monitor Mold Heaters Railroad Crossing Current Monitor |
How to select your product
|
Ready to order? Other ways to order
|
Model | Input/Output | Features | Product |
AC to DC Isolated Signal ConditionerFactory Configured API 6010 G from $369Open Datasheet Download Datasheet |
Specify input range Factory configured 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-900 mAAC Specify output range Factory configured 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
API 6010 G |
AC to DC Isolated Signal ConditionerFactory Configured APD 6010 from $449Open Datasheet Download Datasheet |
Specify input range True RMS 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-1000 mAAC Specify output range 0-1 V to 0-10 V ±1 V, ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 6010 |
AC to DC Isolated Current MeasurementField Configurable Z201-H $199Module power: 85-265 VAC/VDCZ201 $179Module power: 19-40 VDC, 19-28 VACOpen Datasheet Download Datasheet Open Z201-H manual Download Z201-H manual Open Z201 manual Download Z201 manual |
Field selectable input ranges 0-5 Amps AC 0-10 Amps AC Selectable via wiring terminal Field selectable output ranges 0-1 V, 0-5 V, 0-10 V, 2-10 V 0-20 mA, 4-20 mA sink or source |
|
Seneca Z201-H and Z201 |
AC to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPD 6380 from $499Open Datasheet Download Datasheet |
Hundreds of input ranges True RMS 0-40 mVAC to 0-300 VAC 0-4 mAAC to 0-200 mAAC Open APD 6380 Ranges Download APD 6380 Ranges Email APD 6380 Ranges Link 18 output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
APD 6380 |
AC to DC Isolated Signal ConditionersField Selectable Minuteman SetupAPI 6380 G from $439Open Datasheet Download Datasheet |
20 input ranges Order S version for true RMS 0-50 mVAC to 0-250 VAC, 0-5 mAAC to 0-200 mAAC 0-5 mAAC to 0-200 mAAC 16 output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
API 6380 G, API 6380 G S |
AC to DC Isolated Signal Conditioners |
24 input ranges 0-50 mVAC to 0-600 VAC 0-5 mAAC to 0-200 mAAC Like API 6380 G but with additional input ranges 0-300VAC, 0-400VAC, 0-500VAC, 0-600VAC 16 output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
API 6380 G HV, API 6380 G S HV |
IsoSplitter® AC Signal Splitter |
Specify mVAC, VAC or mAAC input range True RMS 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-1000 mAAC Input frequency: 40 Hz to 1000 Hz sinusoidal Specify output range for each channel 2 independent output channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 6393 AC IsoSplitter |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series from $629 |
Specify input range for each channel APD 2016 Ch1: RTD Ch2: AC mV/V/mA APD 2036 Ch1: Potentiometer Ch2: AC mV/V/mA APD 2056 Ch1: Strain gauge Ch2: AC mV/V/mA APD 2066 Ch1: AC mV/V/mA Ch2: AC mV/V/mA APD 2067 Ch1: AC mV/V/mA Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series AC |
AC Input Alarm TripsFactory Configured API 1600 G from $349 |
Specify input range Factory configured 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-900 mAAC API 1600 G Alarm Trips One DPDT contact set, adjustable deadband Standard: HI alarm Optional: LO alarm API 1620 G Dual Alarm Trip Two SPDT contact sets, 1% deadband Standard: HI/LO alarms, normal acting Optional: LO/HI, HI/HI, LO/LO alarms |
|
API 1600 G, API 1620 G |
AC Input Alarm TripsFactory Configured APD 1600 from $379 |
Specify input range Factory configured 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-1000 mAAC APD 1600 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1620 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options |
|
APD 1600, APD 1620 |
AC to DC Isolated Current MeasurementField Configurable Z201-H $199Module power: 85-265 VAC/VDCZ201 $179Module power: 19-40 VDC, 19-28 VACOpen Datasheet Download Datasheet Open Z201-H manual Download Z201-H manual Open Z201 manual Download Z201 manual |
Field selectable input ranges 0-5 Amps AC 0-10 Amps AC Selectable via wiring terminal Field selectable output ranges 0-1 V, 0-5 V, 0-10 V, 2-10 V 0-20 mA, 4-20 mA sink or source |
|
Seneca Z201-H and Z201 |
AC Current SwitchesCS-AC-1 $134 *stock item* |
Input 0-150 Amps AC input Output CS-AC-1 NC solid state relay, 0.15A @ 130 VAC/VDC Output CS-AC-2 NO solid state relay, 0.15 A @ 240 VAC/VDC Power Self-powered via input current |
|
CS-AC Series
|
4 Digit 4-20 mA Loop Powered DisplayField RangeableS315 $150 *stock item* |
Loop Powered Display Input: 4-20 mA Display: 4 digit red LED |
|
S315 |