| Analog DC Voltage and Current Alarms | |||
|---|---|---|---|
| 
 Product brochure Options & accessories Cross reference Regulatory compliance Click on PDF links below for product information | Reference Info Alarm terminology Deadband Relay protection & EMI suppression RFI/EMI Applications Dam bubbler Heater break alarm pH meter auto select Poultry slicer motor current Hydrogen sulfide alarm Fail safe valve control Auto-ranging flow meter Monitor bi-directional flow Pump pressure band alarm Steam Condensate Monitoring | How to select your product 
 | Ready to order? Other ways to order 
 | 
| Model | Input/Output | Features | Product | 
| DC Input Alarm TripsFactory Configured API 1000 G  from $299 | Specify input range Factory configured 0-100 mVDC to 0-300 VDC 0-1 mADC to 0-900 mADC API 1000 G Single Alarm Trip One DPDT contact set, adjustable deadband Standard: HI alarm Optional: LO alarm API 1020 G Dual Alarm Trip Two SPDT contact sets, 1% deadband Standard: HI/LO alarms, normal acting Optional: LO/HI, HI/HI, LO/LO alarms | 
 |  API 1000 G, API 1020 G | 
| DC Input Alarm TripsFactory Configured APD 1000   from $379  | Specify input range Factory configured 0-100 mVDC to 0-300 VDC 0-1 mADC to 0-20 mADC, 4-20 mA APD 1000 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1020 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options | 
 |   APD 1000, APD 1020 | 
| 4-20 mA Input Alarm Trips | 4-20 mA input range Factory configured API 1005 G Single Alarm Trip One DPDT contact set, adjustable deadband Standard: HI alarm Optional: LO alarm API 1025 G Dual Alarm Trip Two SPDT contact sets, 1% deadband Standard: HI/LO alarms, normal acting Optional: LO/HI, HI/HI, LO/LO alarms | 
 |  API 1005 G, API 1025 G | 
| DC Input Alarm TripsField Selectable Minuteman SetupAPI 1080 G  from $379 | 24 Input Ranges 0-50 mV to 0-10 V ±5 V, ±10 V 0-1 mA to 0-20 mA, 4-20 mA API 1080 G Field Configurable Single Alarm One DPDT contact set Adjustable setpoint and deadband API 1090 G Field Configurable Dual Alarms 2 independent SPDT contact sets Two adjustable setpoints each with deadband | 
 |  API 1080 G, API 1090 G Socket sold separately | 
| DC Input Alarm TripsField Selectable Minuteman SetupAPD 1080  from $389 | 24 Input Ranges 0-50 mV to 0-10 V ±5 V, ±10 V 0-1 mA to 0-20 mA, 4-20 mA APD 1080 Field Configurable Single Alarms Two DPST contact sets Adjustable setpoint and deadband 2 form A (NO), 2 form B (NC) contact sets May be field wired for form C operation APD 1090 Field Configurable Dual Alarms 2 independent SPDT contact sets Two adjustable setpoints each with deadband SP 1: form A (NO) and form B (NC) contacts SP 2: form A (NO) and form B (NC) contacts May be field wired for form C operation | 
 |   APD 1080, APD 1090 | 
| Universal Input to DC Isolator/Converter | Configurable Input mV, V, (Bipolar from 75 mV to 20 V) mA (Bipolar up to 20 mA) RTD: Pt100, Pt500, Pt1000, Ni100, KTY81, KTY84, NTC; 3-4 wire Thermocouple: Type J, K, R, S, T, E, B, N, Potentiometer: 500 Ω to 100 kΩ Rheostat: 500 Ω to 25 kΩ Strobe: Alternative to output relay Output One isolated mA or Voltage Sink or source mA Configurable range 1 relay output | 
    |  Z109REG2-1 | 
| Triple Trip AlarmFactory Configured TRA173 call for quoteOpen Datasheet Download Datasheet | Specify input type and range DC voltage to 10 V DC mMilliamps to 20 mA DC voltage up to 2kV DC current to 10A Specify relay output type SPDT relays Specify NO or NC contacts | 
 
 |   TRA173 | 
| DC Current Switches
     CS-DC-1S-12  $165 | Input 0-100 Amps DC Output CS-DC-1S-24 SPDT relay, 5 A @ 240 VAC / 3 A @ 30 VDC Output CS-DC-2S-24 NO Solid state relay, 0.3 A @ 135 VAC/DC Output CS-DC-1S-12 SPDT relay, 5 A @ 240 VAC / 3 A @ 30 VDC Output S-DC-2S-12 NO Solid state relay, 0.3 A @ 135 VAC/DC Power CS-DC-1S-24, CS-DC-2S-24 20-28 VAC/DC Power CS-DC-1S-12, CS-DC-2S-12 12 VAC/DC ±10% | 
   |  CS-DC Series | 