IsoSplitter - Split One Analog Signal Into Two Isolated DC Outputs |
|||
---|---|---|---|
Product brochure Options & accessories Regulatory compliance Click on PDF links below for product information |
Reference Info Ground Loops RFI/EMI LoopTracker and Output Test Sink vs Source Applications Split a 4-20mA RTD signal Split a 4-20mA HVAC signal Split a 4-20mA flowmeter signal Split a 4-20mA pellet flowmeter signal Drive three 4-20mA SCR signals |
How to select your product
|
Ready to order? Other ways to order
|
Model | Input/Output | Features | Product |
Thermocouple Splitter/ConverterFactory Configured Input: One Thermocouple Output 1: Thermocouple Output 2: Thermocouple APD 41390 from $599Open Datasheet Download Datasheet |
Specify Input T/C type, °F or °C range J, K, T, E, R, S, N, B, C, D, G, M, P Temperature range may be limited by the smallest ANSI range of the 3 T/C types you select Specify T/C connection type Differential (std), ungrounded Single-Ended (optional), grounded Specify T/C burnout Output signals if the input T/C goes open circuit Upscale burnout (std) Downscale burnout Last known value Specify Output 1 T/C type, °F or °C range J, K, T, E, R, S, N, B, C, D, G, M, P Specify Output 2 T/C type, °F or °C range J, K, T, E, R, S, N, B, C, D, G, M, P Optional alarm See datasheet for more information No Alarm (std), Hi Alarm, Lo Alarm Non-Latching, Latching, Reset Type Normal Acting or Reverse Acting |
|
![]() APD 41390 |
Thermocouple Splitter/ConverterFactory Configured Input: One Thermocouple Output 1: DC Process Signal Output 2: Thermocouple APD 41391 from $599Open Datasheet Download Datasheet |
Specify Input T/C type, °F or °C range J, K, T, E, R, S, N, B, C, D, G, M, P Temperature range may be limited by the smallest ANSI range of the 2 T/C types you select Specify T/C connection type Differential (std), ungrounded Single-Ended (optional), grounded Specify T/C burnout Output signals if the input T/C goes open circuit Upscale burnout (std) Downscale burnout Last known value Specify Output 1 type and range DC output: V or mA Sink/source mA output Specify Output 2 T/C type, °F or °C range J, K, T, E, R, S, N, B, C, D, G, M, P Optional alarm See datasheet for more information No Alarm (std), Hi Alarm, Lo Alarm Non-Latching, Latching, Reset Type Normal Acting or Reverse Acting |
|
![]() APD 41391 |
Thermocouple Splitter/TransmitterFactory Configured Input: One Thermocouple Output 1: DC process signal Output 2: DC process signal APD 41393 from $599Open Datasheet Download Datasheet |
Specify Input T/C type, °F or °C range J, K, T, E, R, S, N, B, C, D, G, M, P Specify T/C connection type Differential (std), ungrounded Single-Ended (optional), grounded Specify T/C burnout Output signals if the input T/C goes open circuit Upscale burnout (std) Downscale burnout Last known value Specify Output 1 type and range DC output: V or mA Sink/source mA output Specify Output 2 type and range DC output: V or mA Sink/source mA output Optional alarm See datasheet for more information No Alarm (std), Hi Alarm, Lo Alarm Non-Latching, Latching, Reset Type Normal Acting or Reverse Acting |
|
![]() APD 41393 |
IsoSplitter® Signal Splitter |
Specify input range 0-10 mVDC to 100 VDC ±50 mV to ±10 VDC 0-1 mADC to 0-50 mADC, 4-20 mADC Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() APD 4930 DC IsoSplitter |
IsoSplitter® Signal Splitter |
Specify input range Factory Configured 0-10 mVDC to 100 VDC ±50 mV to ±10 VDC 0-1 mADC to 0-50 mADC, 4-20 mADC Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 4393 DC IsoSplitter |
IsoSplitter® Signal Splitter |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu 1000 Ω Ni-Fe 120 Ω Ni or special Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 1393 |
IsoSplitter® Signal Splitter |
Use any full range 100 Ω to 1 MΩ potentiometer Specify output range for each channel 2 independent output channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 3393 Potentiometer IsoSplitter |
IsoSplitter® Strain Gauge Amplifier/Signal Splitter |
Specify input range Factory configured for one 350 Ω (or greater) strain gauge, pressure transducer, pressure sensor, load cell, or bridge Strain gauge mV range: 1 mV to 2000 mV Specify mV/V or mV range mV/V sensitivity X excitation voltage = total mV range Specify excitation voltage 4 to 10 VDC excitation at 30 mA Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 5393 Strain Gauge IsoSplitter |
IsoSplitter® AC Signal Splitter |
Specify mVAC, VAC or mAAC input range True RMS 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-1000 mAAC Input frequency: 40 Hz to 1000 Hz sinusoidal Specify output range for each channel 2 independent output channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 6393 AC IsoSplitter |
IsoSplitter® Frequency Signal Splitter |
Specify frequency range Factory Configured 10-25 Hz to 0-20 kHz 100 mV to 150 VRMS amplitude Sensor power supply available Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 7393 Frequency IsoSplitter |
4 Digit 4-20 mA Loop Powered DisplayField RangeableS315 $150 *stock item* |
Loop Powered Display Input: 4-20 mA Display: 4 digit red LED |
![]() |
![]() S315 |