Thin DIN Signal Conditioners, Converters, Isolators, Transmitters

  • 1 Year Warranty on K-Line Modules
  • Hot-Swappable Design
  • Economical
  • Full I/O/Power Isolation




Click on PDF links below
for product information
Literature and Links
API K-Line product brochure
Seneca accessories and software

Reference Info
Ground Loops
RFI / EMI
Sink vs Source

Seneca
Click to see ALL Seneca products
How to select your product
  • Open pdf datasheet for your model
  • Select model, range, units, options, accessories
  • Contact us if you need assistance
Need a quote?
Ready to order?
Other ways to order
Model Input/Output Features Product

DC to DC Isolated Signal Conditioner


Field Configurable


K109UI  $250 *stock item*

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Configurable Input
Input: 0-20 mA, 4-20 mA,
0-5 VDC, 1-5 VDC, 0-10 VDC, 2-10 VDC,
0-15 VDC, 0-30 VDC

Field Configurable Output
Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS

UL Listed   CE logo
K109UI
K109UI

DC to DC Isolated Transmitter
with Sink/Source Input


Field Configurable


K109S  $250 *stock item*

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Configurable Input
Input: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V


Field Configurable Output
Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS


UL Listed CE logo
K109S
K109S

Universal Input to 4-20 mA
Loop Powered Transmitter


Field Programmable


K121    $165 *stock item*
K121-C  $190 ranged to order

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Programmable Input
Requires EASY-USB for configuration
Input: –150 mV to +150 mV
–30 V to +30V
–24 mA to 24 mA
RTD: Pt100, Pt500, Pt1000, Ni100
Thermocouple: J, K, T, E, R, S, B, N
Potentiometer: 500 Ω to 10 KΩ
Resistance: 1750 Ω

Output: 4-20 mA loop powered
Powered by the output loop

  • Only 6.2 mm wide
  • PC programmable configuration
  • Full 2-way isolation
  • DIN rail mount without tools
  • Powered by 4-20 mA loop

  • CE logo  EX
K121
K121

Thermocouple to DC Isolated Transmitter


Field Configurable


K109TC  $250 *stock item*

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Configurable Input
Input: Thermocouple: J, K, T, E, R, S, N, B

Field Configurable Output
Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS

UL Listed   CE logo
K109TC
K109TC

100 Ω RTD to DC Isolated Transmitter


Field Configurable


K109PT  $250 *stock item*

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Configurable Input
Input: One 100 Ω RTD, 385 Curve RTD, 2, 3, or 4 wire
–150 to 650°C, (–238 to 1202°F), 50°C min. span

Field Configurable Output
Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS

UL Listed   CE logo
K107A
K109PT

RS-485 to RS-485 or
RS-232 to RS-485
Repeaters/Isolators/Amplifiers


K107A  $175
K107B  $175 *stock item*

Open Datasheet
Download Datasheet

Open Installation Manual
Open Installation Manual

Click to see ALL Seneca products

K107A RS-485 to RS-485
Data X: One RS-485 half duplex
Data Y: One RS-485 half duplex

K107B RS-232 to RS-485
Data X: One RS-232 half duplex
Data Y: One RS-485 half duplex

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS

UL Listed   CE logo
K107A K107B
K107A            K107B

USB - UART TTL Converter


EASY-USB  $140 *stock item*

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

EASY-USB Software Link

Programming Kit for K121, T120, T121

Includes
Converter
Software mini CD (or download latest)
Adapter cable (std USB cable not included)
EASY-USB
EASY-USB

K-SUPPLY and KBUS Power Supply
for K-Series Modules


K-SUPPLY  $99 *stock item*
KBUS  $17 *stock item*

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Regulated Power Distribution
Input: 19.2 to 30 VDC
Output: 19.2 to 30 VDC

  • Only 6.2 mm wide
  • Power supply distribution
  • Regulated and isolated
  • Low cost
  • DIN rail mount without tools
  • Power: any 19.2-30 VDC supply

CE logo
K107A
K-SUPPLY                 K-BUS

4 Digit 4-20 mA Loop Powered Display


Field Rangeable


S315  $150 *stock item*
S315-IP66  $310

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Loop Powered Display
Input: 4-20 mA
Display: 4 digit red LED

  • 1/8 DIN panel mount or IP66 housing
  • Scaleable 4 digit display

CE logo
S315
S315