Potentiometer to Analog Signal Conditioners, Converters, Isolators, Transmitters, Alarms

  • 6 Year Warranty on API Modules
  • LoopTracker® I/O LEDs
  • Hot-Swappable Plug-In Design
  • Zero and Span Output Calibration
  • Push to Test Output
  • Full I/O/Power Isolation
Links
Product brochure
Options & accessories
Regulatory compliance


Click on PDF links below
for product information
Reference Info
Ground Loops
RFI/EMI
LoopTracker and Output Test
Sink vs Source

Applications
Manual burner control
Motor load control
Milling machine feed
Phase separtor water level
Damper position
Phase separtor water level
Fail safe valve control
Municipal water tower level
Blower louver position
Steam Condensate Monitoring
How to select your product
  • Open pdf datasheet for your model
  • Select model, range, units, options, accessories
  • Contact us if you need assistance
Need a quote?
Ready to order?
Other ways to order
Model Input/Output Features Product

Potentiometer Input Alarm Trips


Factory Configured

APD 1800  from $379
APD 1820  from $399

Open Datasheet
Download Datasheet
Any full-range potentiometer
0-100 Ω to
0-1 Mega Ω

APD 1800 Single Alarm Trip
Dual SPDT contact sets
Standard: HI alarm, non-latching, normal acting
See data sheet for alarm options

APD 1820 Dual Alarm Trip
2 independent SPDT contact sets
Standard: HI/LO alarms, non-latching, normal acting
See data sheet for alarm options

  • User adjustable setpoint(s)
  • User adjustable deadband(s)
  • 8 Amp SPDT contacts
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm options: LO, HI/HI, LO/LO, band alarm
  • Optional reverse acting
  • Optional latching alarms
  • Push to test/reset
  • Remote push to test/reset
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount without tools
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power

APD 1800UL approved
APD 1800, APD 1820

Potentiometer to DC Isolated Signal Conditioner


Factory Configured

API 4003 G I  from $349

Open Datasheet
Download Datasheet
Input range
Any full-range potentiometer
0-100 Ω to 0-1 Mega Ω

Specify output range
Factory configured
0-1 V to 0-10 V
±1 V to ±10 V
0-1 mA to 0-20 mA, 4-20 mA

  • Hot-swappable plug-in design
  • Replaces Action AP 4003
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option: 85-265 VAC, 60-300 VDC power (+$60)
  • D option: 9-30 VDC power (+$60)


Api 4003G I   UL listed
API 4003 GI

Potentiometer to DC Isolater/Converter


Custom application: 100-900 Ohms to 0-20 mA

TX-4003 (74614)  call for price

Open Datasheet
Download Datasheet

TX-4003 (74614)
Do not substitute with API-4003 G

Input range
100 to 900 Ohms

Output range
0-20 mA sinking
  • Used for Turblex, Siemens, Howden equipment
  • Hot-swappable plug-in design
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Plugs into standard 8-pin socket
  • 9-30 VDC powered


TX-4003   TX-4003

Potentiometer to DC Isolated Signal Conditioner


Factory Configured

APD 4003  from $389

Open Datasheet
Download Datasheet
Input range
Any full-range potentiometer
0-100 Ω to 0-1 Mega Ω

Specify output range
Factory Configured
0-1 V to 0-10 V
±1 V to ±10 V
0-1 mA to 0-20 mA, 4-20 mA

  • Removable plugs
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Selectable sink/source output
  • 20 V output loop power supply
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power

APD4003UL approved
APD 4003

Potentiometer to DC Isolated Signal Conditioner


Field Selectable Minuteman Setup


API 4008 G  from $359

Open Datasheet
Download Datasheet
Any full-range potentiometer
0-100 Ω to 0-1 Mega Ω

18 field configurable outputs
0-1 V to 0-10 V
±1 V to ±10 V
0-2 mA to 0-20 mA, 4-20 mA
  • Minuteman one-minute setup
  • Hot-swappable plug-in design
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option: 85-265 VAC, 60-300 VDC power (+$60)
  • D option: 9-30 VDC power (+$60)


Api 4008G   UL listed
API 4008 G

Potentiometer to DC Isolated Signal Conditioner


Field Selectable Minuteman Setup


APD 4008  from $399

Open Datasheet
Download Datasheet
Any potentiometer
0-100 Ω to 0-1 Mega Ω
0 to 90% offset capable
Can use partial potentiometer ranges

18 field configurable outputs
0-1 V to 0-10 V
±1 V to ±10 V
0-2 mA to 0-20 mA, 4-20 mA
  • Minuteman one-minute setup
  • Removable plugs
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Selectable sink/source output
  • 20 V output loop power supply
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power

APD 4008UL approved
APD 4008

Universal Input to DC Isolated Signal Conditioner


Field Programmable


APD 8000  from $529

*Free I/O Range Setup*
Include your I/O ranges on your order,
and we'll set it up for you!

Open Datasheet
Download Datasheet

Open Feature Summary
Download Feature Summary
Field configurable inputs
DC volts: 35 ranges from ±25mVDC to ±10 VDC
DC mA sinking input, 20 ranges from ±0.5mADC to ±20mADC
Potentiometer: 100Ω min. to 1 MegaΩ max.
Thermocouple: J, K, T, E, R, S, N, B, C, D, G, M, P
RTDs: 2, 3, or 4 wire, 10Ω to 8000Ω RTDs
Thermistor: 44000 series, YSI 400, Spectrum
Custom input available

18 field programmable output ranges
Voltage: 0-1V, 0-2V, 0-4V, 0-5V, 1-5V, 0-8V, 0-10V, 2-10V,
±5V, ±10V
Current: 0-2mA, 0-4mA, 0-8mA, 0-10mA, 2-10mA, 0-16mA,
0-20mA, 4-20mA
Can be wired for sink or source
  • Switch and pushbutton setup
  • Removable plugs
  • Input LoopTracker LED
  • Output test button
  • Full I/O/power isolation
  • Selectable sink/source output
  • 20 V output loop power supply
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power
  • For orders of 5 or more, call us for lead times

APD8000UL approved
APD 8000

Universal Input to DC Isolator/Converter
V, mA, Ohms, TC, RTD


Z109REG2-1  $289

Open Brochure
Download Brochure

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products


Download .dwg CAD Drawing
Download .stp 3-D Drawing

Configurable Input
mV, V, (Bipolar from 75 mV to 20 V)
mA (Bipolar up to 20 mA)
RTD: Pt100, Pt500, Pt1000, Ni100, KTY81, KTY84, NTC; 3-4 wire
Thermocouple: Type J, K, R, S, T, E, B, N,
Potentiometer: 500 Ω to 100 kΩ
Rheostat: 500 Ω to 25 kΩ
Strobe: Alternative to output relay

Output
One isolated mA or Voltage
Sink or source mA
Configurable range
1 relay output

CE UL

Z109REG2-1
Z109REG2-1

IsoSplitter® Signal Splitter
1 Potentiometer Input to 2 DC Outputs


Factory Configured

APD 3393  from $609

Open Datasheet
Download Datasheet
Use any full range 100 Ω to 1 MΩ potentiometer

Specify output range for each channel
2 independent output channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
  • One potentiometer input
  • Two isolated DC output channels
  • Selectable sink/source mA output
  • 20 V output loop power supplies
  • I/O LoopTracker LEDs
  • Output test buttons
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount
  • 45 mm wide
  • Universal power 85-265 VAC, 60-300 VDC
  • D for 9-30 VDC, 10-32 VAC power

Potentiometer IsoSplitterUL approved
APD 3393 Potentiometer IsoSplitter

DuoPak® 2 Channel Isolated Signal Conditioners


Factory Configured

APD 2000 Series  from $629

Specify input range for each channel

APD 2003 Ch1: DC mV/V/mA Ch2: Potentiometer
APD 2013 Ch1: RTD Ch2: Potentiometer
APD 2033 Ch1: Potentiometer Ch2: Potentiometer
APD 2035 Ch1: Potentiometer Ch2: Strain gauge
APD 2036 Ch1: Potentiometer Ch2: AC mV/V/mA
APD 2037 Ch1: Potentiometer Ch2: Frequency

Specify output range for each channel
2 independent channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA

  • Optional I/O reversal
  • I/O LoopTracker LEDs
  • Selectable sink/source mA output
  • 20 V output loop power supplies
  • Output test buttons
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount
  • 45 mm wide
  • Universal power 85-265 VAC, 60-300 VDC
  • D for 9-30 VDC, 10-32 VAC power


DuoPakUL approved
APD 2000 Series Potentiometer

Analog To Resistance Converter


Factory Configured

ATR167  call for quote

Open Datasheet
Download Datasheet
Specify input type and range
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
Millivolt/Volts
Potentiometer or resistance

Specify output range
Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom
  • High resolution true analog output
  • 3-wire pot or 2-wire variable resistor output simulation
  • Front zero and span pots
  • Output level LED
  • Full I/O/power isolation
  • Universal power options: 8 VDC to 280 VAC
Typical applications include
  • Convert a thermocouple to RTD signal to
    match dissimilar equipment
  • Automatic gain control
Analog To Resistance Converter ATR167
ATR167

Analog To Potentiometer Converter


Factory Configured

ATP 168  call for quote

Open Datasheet
Download Datasheet
Specify input type and range
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
Millivolt/Volts
Potentiometer or resistance

Specify output range
Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom
  • Convert a signal to a potentiometer output
  • 3-wire pot or 2-wire variable resistor output simulation
  • 8 bit output resolution (255 count)
  • Front zero and span pots
  • Output level LED
  • Full I/O/power isolation
  • Universal power options: 8 VDC to 280 VAC
Typical applications include
  • Replace mechanical pot used for control of
    existing machinery
  • Automatic control of instrument gain or offset
  • Provide programmable adjustment for delays,
    filters or time constants.
Analog To Potentiometer Converter ATP168
ATP168

Head-Mount Universal Transmitter, Isolated


Field Programmable


Fits DIN Form B Heads

T121  $159 *stock item*

T121-C  $179 pre-programmed to order

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Programmable
Requires EASY-USB for configuration

Input: Pt100 or Ni100, Pt500, Pt1000
J, K, R, S, T, B, E, N
Potentiometer
mVDC, VDC

Selectable Output
Output: 4-20 mA, 20-4 mA

  • Order T121-C for pre-programmed I/O
  • 44 mm dia
  • I/O isolation
  • DIN B with 5.8mm (0.228"dia) center hole
  • Power: 7 to 30 VDC current loop

T121   CE logo

T121

USB - UART TTL Converter


EASY-USB  $140 *stock item*

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

EASY-USB Software Link

Programming Kit for K121, T120, T121

Includes
Converter
Software mini CD (or download latest)
Adapter cable (std USB cable not included)
EASY-USB
EASY-USB

4 Digit 4-20 mA Loop Powered Display


Field Rangeable


S315  $150 *stock item*
S315-IP66  $310

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Loop Powered Display
Input: 4-20 mA
Display: 4 digit red LED

  • 1/8 DIN panel mount or IP66 housing
  • Scaleable 4 digit display

CE logo
S315
S315