Analog DC to DC Signal Conditioners, Converters, Isolators, Transmitters |
|||
---|---|---|---|
![]()
![]() for product information |
Literature and LinksAPI product brochure Options & accessories Cross reference UL ApprovalsAPI modules USA
APD modules USA Ground Loops RFI / EMI LoopTracker and Output Test Sink vs Source |
ApplicationsMonitoring motor speed with a PLC Building heat SCR control Manual override of computer control Monitor pressure with a PLC Control & monitor with one flow meter Monitor product moved by conveyor Pharmaceutical process validation Dam bubbler SCR drive voltage Blower speed DC motor voltage and current DC motor current Bindicator level xmtr to PLC Special API4300 for engine speed Contol conveyor material Sewage pumping stations Hydraulic fracking control Anemometer interface to PLC Special API4300 for engine speed |
How to Order
|
Model | Input/Output | Features | Product |
DC to DC Isolated Signal ConditionersFactory Configured API 4300 G |
API 4300 G Specify input range Factory configured 0-100 mVDC to 0-500 VDC ±100 mVDC to ±10 VDC 0-100 μADC to 0-900 mADC Specify output range Factory configured 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA 0-20 mA to 0-50 mA with HC output option API 4310 G Narrow/Low Input Specify input range Factory configured 0-10 mV to 0-100 mV ±10 mV to ±100 mV 0-100 μA to 0-1 mA Specify output range Factory configured 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA I/O reversal available |
|
![]() ![]() API 4300 G, API 4310 G |
DC to DC Isolated Signal ConditionerFactory Configured APD 4300Open Datasheet Download Datasheet |
APD 4300 Specify input range 0-100 mVDC to 0-300 VDC ±100 mVDC to ±10 VDC 0-1 mADC to 0-1000 mADC, 4-20 mA Specify output range Factory configured 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA I/O reversal available APD 4300 PLC Input range: 4-20 mA Output range: 4-20 mA |
|
![]() ![]() APD 4300 |
DC to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPI 4380 GOpen Datasheet Download Datasheet |
24 Field configurable inputs |
|
![]() ![]() API 4380 G |
DC to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPD 4380Open Datasheet Download Datasheet |
53 field configurable input ranges 0-10 mVDC to 0-130 VDC ±5 mV to ±65 VDC 0-200 μA to 0-50 mADC 18 Field configurable output ranges 0-1 V to 0-10 VDC ±5 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
![]() ![]() APD 4380 |
High Accuracy DC to DC Isolated Signal ConditionerField ProgrammableAPD 4381Open Datasheet Download Datasheet |
54 field configurable input ranges 0-50 mVDC to 0-10 VDC ±25 mV to ±10 VDC 0-500 μA to 0-20 mADC Custom input range available 18 field configurable output ranges 0-1 V to 0-10 VDC ±5 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
![]() ![]() ![]() APD 4381 |
DC to DC Isolated Signal ConditonerField Selectable Minuteman SetupAPI 4385 GOpen Datasheet Download Datasheet |
24 field configurable inputs -50-0 mVDC to 0-20 VDC, 20-40 VDC 0-200 μADC to 0-40 mADC, 10-50 mADC Selectable zero offset 16 field configurable outputs 0-1 V to 0-10 V ±5 V, ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
![]() ![]() API 4385 G |
DC to DC Isolated Signal Conditoner |
24 field configurable inputs 0-1 VDC to ±200 VDC 16 field configurable outputs 0-1 V to 0-10 V ±1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
![]() ![]() API 4380 GHV3 |
DC to DC Isolated Signal Conditoner |
8 selectable input ranges 7 standard plus 1 factory set 0-100 VDC to 0-1200 VDC, and custom specify custom range if required (2000 VDC max.) 18 selectable output ranges 0-1 V to 0-10 V, ±5 V, ±10 V, 0-2 mA to 0-20 mA, 4-20 mA, |
|
![]() APD HV-DC |
IsoSplitter® Signal Splitter |
Specify input range 0-10 mVDC to 100 VDC ±50 mV to ±10 VDC 0-1 mADC to 0-50 mADC, 4-20 mADC Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 4930 DC IsoSplitter |
IsoSplitter® Signal Splitter |
Specify input range Factory Configured 0-10 mVDC to 100 VDC ±50 mV to ±10 VDC 0-1 mADC to 0-50 mADC, 4-20 mADC Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 4393 DC IsoSplitter |
Universal Input to DC Isolated Signal ConditionerField ProgrammableAPD 8000Open Feature Summary Download Feature Summary Open Datasheet Download Datasheet |
Field configurable inputs DC volts: 35 ranges from ±25mVDC to ±10 VDC DC mA sinking input, 20 ranges from ±0.5mADC to ±20mADC Potentiometer: 100Ω min. to 1 MegaΩ max. Thermocouple: J, K, T, E, R, S, N, B, C, D, G, M, P RTDs: 2, 3, or 4 wire, 10Ω to 8000Ω RTDs Thermistor: 44000 series, YSI 400, Spectrum Custom input available 18 field programmable output ranges Voltage: 0-1V, 0-2V, 0-4V, 0-5V, 1-5V, 0-8V, 0-10V, 2-10V, ±5V, ±10V Current: 0-2mA, 0-4mA, 0-8mA, 0-10mA, 2-10mA, 0-16mA, 0-20mA, 4-20mA Can be wired for sink or source |
|
![]() ![]() ![]() APD 8000 |
DC to DC Isolated Signal ConditionerField ConfigurableK109UIOpen Datasheet Download Datasheet Open Installation Manual Download Installation Manual |
Field Configurable Input Input: 0-20 mA, 4-20 mA, 0-5 VDC, 1-5 VDC, 0-10 VDC, 2-10 VDC, 0-15 VDC, 0-30 VDC Field Configurable Output Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA, 0-5 V, 1-5 V, 0-10 V, 10-0 V |
![]() ![]() ![]() |
![]() K109UI |
DC to DC Isolated Transmitter |
Field Configurable Input Input: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA, 0-5 V, 1-5 V, 0-10 V, 10-0 V Field Configurable Output Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA, 0-5 V, 1-5 V, 0-10 V, 10-0 V |
![]() ![]() ![]() |
![]() K109S |
Universal Input to 4-20 mA Loop Powered TransmitterField ProgrammableK121Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual |
Field Programmable Input Input: –150 mV to +150 mV –30 V to +30V –24 mA to 24 mA RTD: Pt100, Pt500, Pt1000, Ni100 Thermocouple: J, K, T, E, R, S, B, N Potentiometer: 500 Ω to 10 KΩ Resistance: 1750 Ω Output: 4-20 mA loop powered Powered by the output loop |
![]() ![]() ![]() |
![]() K121 |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series |
Specify input range for each channel APD 2000 Ch1: DC mV/V/mA Ch2: DC mV/V/mA APD 2001 Ch1: DC mV/V/mA Ch2: RTD APD 2003 Ch1: DC mV/V/mA Ch2: Potentiometer APD 2005 Ch1: DC mV/V/mA Ch2: Strain gauge APD 2006 Ch1: DC mV/V/mA Ch2: AC mV, V, mA APD 2007 Ch1: DC mV/V/mA Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
![]() ![]() APD 2000 Series DC |
DC to DC Signal Conditioners |
Specify input ranges Factory configured Input negative is common 0-100 mV to 0-10 V ±100 mV to ±10 V 0-1 mA to 0-20 mA, 4-20 mA Specify output range Factory configured 0-1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
![]() API 4400 G to API 4408 G |
Head-Mount Universal Transmitter, IsolatedField ProgrammableFits DIN Form B Heads T121Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual |
Programmable Input: Pt100 or Ni100, Pt500, Pt1000 J, K, R, S, T, B, E, N Potentiometer mVDC, VDC Selectable Output Output: 4-20 mA, 20-4 mA |
|
![]() ![]() ![]() T121 |
USB - UART TTL ConverterEASY-USBOpen Datasheet Download Datasheet Open Installation Manual Download Installation Manual EASY-USB Software Link |
Programming kit for K121 Converter Software mini CD (or download latest) Adapter cable (std USB cable not included) |
![]() EASY-USB |
|
4 Digit 4-20 mA Loop Powered DisplayField RangeableS315 |
Loop Powered Display Input: 4-20 mA Display: 4 digit red LED |
![]() ![]() |