Signal Conditioners, Converters, Isolators, Transmitters |
|||
---|---|---|---|
Product brochure Options & accessories Regulatory compliance Click on PDF links below for product information |
Reference Info Ground Loops RFI / EMI LoopTracker and Output Test Sink vs Source |
How to select your product
|
Ready to order? Other ways to order
|
Model | Input/Output | Features | Product |
Thermocouple to DC Isolated Signal ConditionerFactory Configured APD 4131 from $469Open Datasheet Download Datasheet |
Specify T/C type and °F or °C temperature range Factory configured Thermocouples J, K, T, E, R, S, N, B, C, D, G, M, P ±0.25°C Accuracy Microprocessor-based linearization Specify output range Factory configured analog output 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 4131 |
Thermocouple to Dual Thermocouple Splitter/ConverterFactory Configured APD 41390 from $599Open Datasheet Download Datasheet |
Specify T/C input type and range T/C: J, K, T, E, R, S, N, B, C, D, G, M, P Temperature range may be limited by the smallest ANSI range of the 3 T/C types you select Upscale burnout (std), downscale burnout or last known value Specify output types and ranges Channel 1 Thermocouple output type Channel 2 Thermocouple output type Alarm options Hi, Lo, latching, failsafe, reverse |
|
APD 41390 |
Thermocouple to DC and Thermocouple Splitter/ConverterFactory Configured APD 41391 from $599Open Datasheet Download Datasheet |
Specify T/C input type and range T/C: J, K, T, E, R, S, N, B, C, D, G, M, P Temperature range may be limited by the smallest ANSI range of the 2 T/C types you select Upscale burnout (std), downscale burnout or last known value Specify output types and ranges Channel 1 Process DC output: V or mA Sink/source mA output Channel 2 Thermocouple output type Alarm options Hi, Lo, latching, failsafe, reverse |
|
APD 41391 |
Thermocouple to Dual DC Splitter/TransmitterFactory Configured APD 41393 from $599Open Datasheet Download Datasheet |
Specify T/C input type and range T/C: J, K, T, E, R, S, N, B, C, D, G, M, P Specify DC output types and ranges Channel 1 Process DC output: V or mA Sink/source mA output Channel 2 Process DC output: V or mA Sink/source mA output Alarm options Hi, Lo, latching, failsafe, reverse |
|
APD 41393 |
Universal Input to DC Isolated Signal ConditionerField ProgrammableAPD 8000 from $529*Free I/O Range Setup* Include your I/O ranges on your order, and we'll set it up for you! Open Datasheet Download Datasheet Open Feature Summary Download Feature Summary |
Field configurable inputs DC volts: 35 ranges from ±25mVDC to ±10 VDC DC mA sinking input, 20 ranges from ±0.5mADC to ±20mADC Potentiometer: 100Ω min. to 1 MegaΩ max. Thermocouple: J, K, T, E, R, S, N, B, C, D, G, M, P RTDs: 2, 3, or 4 wire, 10Ω to 8000Ω RTDs Thermistor: 44000 series, YSI 400, Spectrum Custom input available 18 field programmable output ranges Voltage: 0-1V, 0-2V, 0-4V, 0-5V, 1-5V, 0-8V, 0-10V, 2-10V, ±5V, ±10V Current: 0-2mA, 0-4mA, 0-8mA, 0-10mA, 2-10mA, 0-16mA, 0-20mA, 4-20mA Can be wired for sink or source |
|
APD 8000 |
DC Input Alarm TripsFactory Configured APD 1000 from $369 |
Specify input range Factory configured 0-100 mVDC to 0-300 VDC 0-1 mADC to 0-20 mADC, 4-20 mA APD 1000 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1020 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options |
|
APD 1000, APD 1020 |
DC Input Alarm TripsField Selectable Minuteman SetupAPD 1080 from $369 |
24 Input Ranges 0-50 mV to 0-10 V ±5 V, ±10 V 0-1 mA to 0-20 mA, 4-20 mA APD 1080 Field Configurable Single Alarms Two DPST contact sets Adjustable setpoint and deadband 2 form A (NO), 2 form B (NC) contact sets May be field wired for form C operation APD 1090 Field Configurable Dual Alarms 2 independent SPDT contact sets Two adjustable setpoints each with deadband SP 1: form A (NO) and form B (NC) contacts SP 2: form A (NO) and form B (NC) contacts May be field wired for form C operation |
|
APD 1080, APD 1090 |
DC to DC Isolated Signal ConditionerFactory Configured APD 4300 from $399Open Datasheet Download Datasheet |
APD 4300 Specify input range 0-100 mVDC to 0-300 VDC ±100 mVDC to ±10 VDC 0-1 mADC to 0-1000 mADC, 4-20 mA Specify output range Factory configured 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA I/O reversal available APD 4300 PLC Input range: 4-20 mA Output range: 4-20 mA |
|
APD 4300 |
DC to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPD 4380 from $419Open Datasheet Download Datasheet |
53 field configurable input ranges 0-10 mVDC to 0-130 VDC ±5 mV to ±65 VDC 0-200 μA to 0-50 mADC 18 Field configurable output ranges 0-1 V to 0-10 VDC ±5 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
APD 4380 |
IsoSplitter® Signal Splitter |
Specify input range 0-10 mVDC to 100 VDC ±50 mV to ±10 VDC 0-1 mADC to 0-50 mADC, 4-20 mADC Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 4930 DC IsoSplitter |
IsoSplitter® Signal Splitter |
Specify input range Factory Configured 0-10 mVDC to 100 VDC ±50 mV to ±10 VDC 0-1 mADC to 0-50 mADC, 4-20 mADC Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 4393 DC IsoSplitter |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series from $629 |
Specify input range for each channel APD 2000 Ch1: DC mV/V/mA Ch2: DC mV/V/mA APD 2001 Ch1: DC mV/V/mA Ch2: RTD APD 2003 Ch1: DC mV/V/mA Ch2: Potentiometer APD 2005 Ch1: DC mV/V/mA Ch2: Strain gauge APD 2006 Ch1: DC mV/V/mA Ch2: AC mV, V, mA APD 2007 Ch1: DC mV/V/mA Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series DC |
AC Input Alarm TripsFactory Configured APD 1600 from $379 |
Specify input range Factory configured 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-1000 mAAC APD 1600 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1620 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options |
|
APD 1600, APD 1620 |
AC to DC Isolated Signal ConditionerFactory Configured APD 6010 from $449Open Datasheet Download Datasheet |
Specify input range True RMS 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-1000 mAAC Specify output range 0-1 V to 0-10 V ±1 V, ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 6010 |
AC to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPD 6380 from $499Open Datasheet Download Datasheet |
Hundreds of input ranges True RMS 0-40 mVAC to 0-300 VAC 0-4 mAAC to 0-200 mAAC Open APD 6380 Ranges Download APD 6380 Ranges Email APD 6380 Ranges Link 18 output ranges 0-1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
APD 6380 |
IsoSplitter® AC Signal Splitter |
Specify mVAC, VAC or mAAC input range True RMS 0-50 mVAC to 0-300 VAC 0-1 mAAC to 0-1000 mAAC Input frequency: 40 Hz to 1000 Hz sinusoidal Specify output range for each channel 2 independent output channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 6393 AC IsoSplitter |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series from $629 |
Specify input range for each channel APD 2016 Ch1: RTD Ch2: AC mV/V/mA APD 2036 Ch1: Potentiometer Ch2: AC mV/V/mA APD 2056 Ch1: Strain gauge Ch2: AC mV/V/mA APD 2066 Ch1: AC mV/V/mA Ch2: AC mV/V/mA APD 2067 Ch1: AC mV/V/mA Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series AC |
Frequency Input Alarm TripsFactory Configured APD 1700 from $379 |
Specify input range Factory configured 0-25 Hz to 0-20 kHz 100 mV to 150 V RMS Any waveform with minimum 100 mV amplitude change Use with 2 wire, 3 wire NPN or PNP sensors APD 1700 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1720 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options |
|
APD 1700, APD 1720 |
Frequency to DC Isolated Signal ConditionerFactory Configured APD 7010 from $429Open Datasheet Download Datasheet |
Specify input range Factory configured 0-25 Hz to 0 to 20 kHz 100 mV to 150 VRMS amplitude Sensor power supply available Specify output range 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 7010 |
Frequency to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPD 7580 from $429Open Datasheet Download Datasheet |
30 field configurable input ranges Low range: 0-100 Hz to 0-1500 Hz High range: 0-2 kHz to 0-30 kHz 100 mV to 150 VRMS amplitude Sensor power supply available 16 field configurable outputs 0-1 V to 0-10 VDC ±1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
APD 7580 |
IsoSplitter® Frequency Signal Splitter |
Specify frequency range Factory Configured 10-25 Hz to 0-20 kHz 100 mV to 150 VRMS amplitude Sensor power supply available Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 7393 Frequency IsoSplitter |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series from $629 |
Specify input range for each channel APD 2007 Ch1: DC mV/V/mA Ch2: Frequency APD 2017 Ch1: RTD Ch2: Frequency APD 2037 Ch1: Potentiometer Ch2: Frequency APD 2057 Ch1: Strain gauge Ch2: Frequency APD 2067 Ch1: AC mV/V/mA Ch2: Frequency APD 2077 Ch1: Frequency Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series Frequency |
DC to Frequency Isolated Signal ConditionersField Selectable Minuteman SetupAPD 7500 from $429 |
24 field configurable inputs 0-50 mVDC to ±10 VDC 0-1 mADC to 0-20 mADC APD 7500 DC to Frequency Transmitters 30 field selectable outputs Low range: 0-100 Hz to 0-1500 Hz High range: 0-2 kHz to 0-30 kHz MOSFET output std., TTL optional Can be wired for MOSFET or TTL output 50% duty cycle square wave output APD 7500 SS DC to Low Frequency Transmitters 30 field selectable outputs Low range: 0-1 Hz to 0-15 Hz High range: 20 Hz to 300 Hz Can be wired for MOSFET or TTL output 50% duty cycle square wave output |
|
APD 7500, APD 7500 SS |
Potentiometer Input Alarm TripsFactory Configured APD 1800 from $379 |
Any full-range potentiometer 0-100 Ω to 0-1 Mega Ω APD 1800 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1820 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options |
|
APD 1800, APD 1820 |
Potentiometer to DC Isolated Signal ConditionerFactory Configured APD 4003 from $389Open Datasheet Download Datasheet |
Input range Any full-range potentiometer 0-100 Ω to 0-1 Mega Ω Specify output range Factory Configured 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 4003 |
Potentiometer to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPD 4008 from $399Open Datasheet Download Datasheet |
Any potentiometer 0-100 Ω to 0-1 Mega Ω 0 to 90% offset capable Can use partial potentiometer ranges 18 field configurable outputs 0-1 V to 0-10 V ±1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
APD 4008 |
IsoSplitter® Signal Splitter |
Use any full range 100 Ω to 1 MΩ potentiometer Specify output range for each channel 2 independent output channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 3393 Potentiometer IsoSplitter |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series from $629 |
Specify input range for each channel APD 2003 Ch1: DC mV/V/mA Ch2: Potentiometer APD 2013 Ch1: RTD Ch2: Potentiometer APD 2033 Ch1: Potentiometer Ch2: Potentiometer APD 2035 Ch1: Potentiometer Ch2: Strain gauge APD 2036 Ch1: Potentiometer Ch2: AC mV/V/mA APD 2037 Ch1: Potentiometer Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series Potentiometer |
Thermocouple Input Alarm TripsFactory Configured APD 1200 from $379 |
Specify T/C type and °F or °C temperature range Factory configured Thermocouple J, K, T, E, R, S, N, B, C, D, G, M, P 100°F (55°C) recommended minimum span APD 1200 Single Alarm Trip Dual DPST contact set Standard: HI alarm, normal acting, set/reset adjustments, non-latching APD 1220 Dual Alarm Trip Two DPST contact sets Standard: HI/LO alarms, normal acting, two set/reset adjustments, non-latching |
|
APD 1200, APD 1220 |
RTD Input Alarm TripsFactory Configured APD 1400 from $369 |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω: 0.00385α, 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special APD 1400 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1420 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options |
|
APD 1400, APD 1420 |
RTD or Thermistor Input Alarm TripsFactory Configured APD 1401 from $379 |
RTD: specify type, 2, 3 or 4 wire, and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω: 0.00385α, 0.003916α, 0.00392α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special Thermistor: specify type and temperature range. For other sensor types provide temperature-resistance chart. Factory configured 44004/44033 2.252 kΩ at 25°C 44005/44030 3.000 kΩ at 25°C 44007/44034 5.000 kΩ at 25°C 44006/44031 10.00 kΩ at 25°C 44008/44032 30.00 kΩ at 25°C YSI 400 2.252 kΩ at 25°C Spectrum 1003k 1 kΩ APD 1401 Single Alarm Trip Dual DPST contact sets Standard: HI alarm, non-latching, normal acting APD 1421 Dual Alarm Trip Two DPST contact sets Standard: HI/LO alarms, normal acting, two set/reset adjustments, non-latching See data sheet for alarm options |
|
APD 1401, APD 1421 |
RTD to DC Isolated TransmitterFactory Configured APD 4001 from $449Open Datasheet Download Datasheet |
Specify RTD type and temperature range 10 Ω to 2000 Ω RTD including 100 Ω: 0.00385α, 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or special Specify output range 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 4001 |
RTD or Thermistor Input to DC Isolated TransmitterFactory Configured APD 4002 from $459Open Datasheet Download Datasheet |
Factory set input range RTD: 2, 3, or 4 wire, 10 Ω to 8000 Ω RTD Thermistor: 44000 series, YSI 400, Spectrum Custom input available Factrory set output range Voltage: 0-1 V to 0-10 V, ±5 V, ±10 V Current: 0-2 mA to 4-20 mA Can be wired for sink or source |
|
APD 4002 |
IsoSplitter® Signal Splitter |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu 1000 Ω Ni-Fe 120 Ω Ni or special Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 1393 |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series from $609 |
Specify input range for each channel APD 2001 Ch1: DC mV/V/mA Ch2: RTD APD 2011 Ch1: RTD Ch2: RTD APD 2013 Ch1: RTD Ch2: Potentiometer APD 2015 Ch1: RTD Ch2: Strain gauge APD 2016 Ch1: RTD Ch2: AC mV/V/mA APD 2017 Ch1: RTD Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series RTD |
Alarm Trip for 1 to 4 Sensors:
APD 1500 from $379 |
Specify Strain gauge mV/V rating, mV range, Excitation voltage Factory configured 100 Ω to 10000 Ω strain gauge 5 mV to 2000 mV 1-10 VDC excitation Accepts one sensor for input APD 1500 Single Alarm Trip Dual SPDT contact sets Standard: HI alarm, non-latching, normal acting See data sheet for alarm options APD 1520 Dual Alarm Trip 2 independent SPDT contact sets Standard: HI/LO alarms, non-latching, normal acting See data sheet for alarm options |
|
APD 1500, APD 1520 |
Isolated DC Amplifier for One Sensor:
APD 4051 from $389Open Datasheet Download Datasheet |
Specify input range Factory Configured One 350 Ω stain gauge, load cell or bridge sensor 1 mV to 2000 mV Accepts one sensor for input Specify excitation voltage Factory Configured 4 to 10 VDC, 30 mA max. Specify output range Factory Configured 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 4051 |
Non-Isolated DC Amplifier for 1 Sensor
Field Selectable Minuteman SetupAPD 4058 from $429Open Datasheet Download Datasheet Email Datasheet Link |
Field configurable 0-5 mVDC to 0-1200 mVDC Accepts one sensor for input Field settable excitation voltage 0-10 VDC in 1 VDC steps, 30 mA drives one sensor 18 field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
APD 4058 |
Isolated DC Amplifier for 1 to 4 Sensors:
Field Selectable Minuteman SetupAPD 4059 from $469Open Datasheet Download Datasheet Email Datasheet Link |
Field configurable 0-5 mVDC to 0-400 mVDC Field settable excitation voltage 0-10 VDC in 1 VDC steps, 120 mA Accepts one to four sensors for input 18 field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
APD 4059 |
Isolated DC Amplifier for 1 to 4 Sensors with
|
Field configurable input 0-5 mVDC to 0-400 mVDC Field settable excitation voltage 0-10 VDC in 1 VDC steps, 120 mA Use internal or external calibration resistor Specify calibration resistor value if required Accepts one to four sensors for input 18 field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA Zero Offset (Tare) ±100% of span in 15% increments |
|
APD 4059CR |
IsoSplitter® Strain Gauge Amplifier/Signal Splitter |
Specify input range Factory configured for one 350 Ω (or greater) strain gauge, pressure transducer, pressure sensor, load cell, or bridge Strain gauge mV range: 1 mV to 2000 mV Specify mV/V or mV range mV/V sensitivity X excitation voltage = total mV range Specify excitation voltage 4 to 10 VDC excitation at 30 mA Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 5393 Strain Gauge IsoSplitter |
DuoPak® 2 Channel Isolated Signal ConditionersChoose Your Factory Configuration APD 2000 Series from $629 |
Specify input range for each channel Accepts one sensor for each input channel APD 2005 Ch1: DC mV/V/mA Ch2: Strain gauge APD 2015 Ch1: RTD Ch2: Strain gauge APD 2035 Ch1: Potentiometer Ch2: Strain gauge APD 2055 Ch1: Strain gauge Ch2: Strain gauge APD 2056 Ch1: Strain gauge Ch2: AC mV/V/mA APD 2057 Ch1: Strain gauge Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series Strain Gauge |