Analog DC to Frequency or Pulse Converters and Transmitters |
|||
---|---|---|---|
Product brochure Options & accessories Regulatory compliance Click on PDF links below for product information |
Reference Info Ground loops RFI/EMI LoopTracker and Output Test Sink vs source Applications Remote monitoring of motor speed HVAC variable air volume control Hall-effect flow sensor Auto-ranging flow meter Control and record water flow Isolate & convert flow meter signal Isolate & convert gas flow meter signal |
How to select your product
|
Ready to order? Other ways to order
|
Model | Input/Output | Features | Product |
Frequency to DC Isolated Signal ConditionerFactory Configured API 7010 G from $409Open Datasheet Download Datasheet |
Specify input range Factory configured 0-25 Hz to 0 to 20 kHz 100 mV to 150 VRMS amplitude Sensor power supply available Specify output range Factory configured 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
API 7010 G |
Frequency to DC Isolated Signal ConditionerFactory Configured APD 7010 from $429Open Datasheet Download Datasheet |
Specify input range Factory configured 0-25 Hz to 0 to 20 kHz 100 mV to 150 VRMS amplitude Sensor power supply available Specify output range 0-1 V to 0-10 V ±1 V to ±10 V 0-1 mA to 0-20 mA, 4-20 mA |
|
APD 7010 |
Frequency to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPD 7580 from $429Open Datasheet Download Datasheet |
30 field configurable input ranges Low range: 0-100 Hz to 0-1500 Hz High range: 0-2 kHz to 0-30 kHz 100 mV to 150 VRMS amplitude Sensor power supply available 16 field configurable outputs 0-1 V to 0-10 VDC ±1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
APD 7580 |
Frequency to DC Isolated Signal ConditionerField Selectable Minuteman SetupAPI 7580 G from $429Open Datasheet Download Datasheet |
30 field configurable input ranges Low range: 0-100 Hz to 0-1500 Hz High range: 0-2 kHz to 0-30 kHz 100 mV to 150 VRMS amplitude Sensor power supply available 16 Field configurable outputs 0-1 V to 0-10 VDC ±1 V to ±10 V 0-2 mA to 0-20 mA, 4-20 mA |
|
API 7580 G Socket sold separately |
IsoSplitter® Frequency Signal Splitter |
Specify frequency range Factory Configured 10-25 Hz to 0-20 kHz 100 mV to 150 VRMS amplitude Sensor power supply available Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 7393 Frequency IsoSplitter |
DuoPak® 2 Channel Isolated Signal ConditionersFactory Configured APD 2000 Series from $629 |
Specify input range for each channel APD 2007 Ch1: DC mV/V/mA Ch2: Frequency APD 2017 Ch1: RTD Ch2: Frequency APD 2037 Ch1: Potentiometer Ch2: Frequency APD 2057 Ch1: Strain gauge Ch2: Frequency APD 2067 Ch1: AC mV/V/mA Ch2: Frequency APD 2077 Ch1: Frequency Ch2: Frequency Specify output range for each channel 2 independent channels 0-1 V to 0-20 V ±1 V to ±10 V 0-1 mA to 0-25 mA, 4-20 mA |
|
APD 2000 Series Frequency |
Zero Speed (Stall) MonitorFactory Configured STM156 call for quoteOpen Datasheet Download Datasheet |
Specify input type Frequency input Low level sine or sawtooth (200mVpp - 20Vpp) 24VDC pulse external source (0.2 - 50VDC) NAMUR proximity sensor or contact (8V) 3-wire NPN proximity sensor 15V auxiliary 3-wire PNP proximity sensor 15V auxiliary 3-wire NPN proximity sensor 24V auxiliary 3-wire PNP proximity sensor 24V auxiliary 2-wire 24VDC/AC proximity sensor 24V auxiliary Specify output type and options Adjustable trip point and delays One or two relays Trip speed delay time range Start up delay time range External control options |
|
STM156 |
Analog To Resistance ConverterFactory Configured ATR167 call for quoteOpen Datasheet Download Datasheet |
Specify input type and range RTD Thermocouple Frequency to 5kHz Pulse input from proximity sensor Millivolt/Volts Potentiometer or resistance Specify output range Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom |
|
ATR167 |
Analog To Potentiometer ConverterFactory Configured ATP 168 call for quoteOpen Datasheet Download Datasheet |
Specify input type and range RTD Thermocouple Frequency to 5kHz Pulse input from proximity sensor Millivolt/Volts Potentiometer or resistance Specify output range Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom |
|
ATP168 |
Process Signal to Bi-Polar DC Signal ConverterFactory Configured BSC133 call for quoteBSC133 Data Sheet BSC133 More Information |
Specify input type and range AC/DC current/millivolt/volts pH/ORP RTD Thermocouple Frequency to 5kHz Pulse input from proximity sensor LVDT Potentiometer or resistance Specify output type and range Bi-polar volts; ±1V to ±20V Bi-polar mA; ±1mA to ±20mA Output Options
|
|
BSC133 |
4 Digit 4-20 mA Loop Powered DisplayField RangeableS315 $150 *stock item* |
Loop Powered Display Input: 4-20 mA Display: 4 digit red LED |
|
S315 |