Thin DIN Signal Conditioners, Converters, Isolators, Transmitters

  • 1 Year Warranty on K-Line Modules
  • Hot-Swappable Design
  • Economical
  • Full I/O/Power Isolation




Click on PDF links below
for product information

Literature and Links


API K-Line product brochure

Seneca accessories and software

Reference Info


Ground Loops
RFI / EMI
Sink vs Source



Seneca

Click to see ALL Seneca products


Call API today for information and pricing!

How to Order

  1. Select a model
  2. See data sheet for ordering info and power options
  3. Request an API price list via chat
  4. Stock to 3 week typical lead time (USA customers)
  5. To place your order
Model Input/Output Features Product

DC to DC Isolated Signal Conditioner


Field Configurable


K109UI

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Configurable Input
Input: 0-20 mA, 4-20 mA,
0-5 VDC, 1-5 VDC, 0-10 VDC, 2-10 VDC,
0-15 VDC, 0-30 VDC

Field Configurable Output
Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS

UL Listed   CE logo 
K109UI
K109UI

DC to DC Isolated Transmitter
with Sink/Source Input


Field Configurable


K109S

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Configurable Input
Input: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V


Field Configurable Output
Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS


UL Listed CE logo 
K109S
K109S

Universal Input to 4-20 mA Loop Powered Transmitter


Field Programmable


K121

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Programmable Input
Input: –150 mV to +150 mV
–30 V to +30V
–24 mA to 24 mA
RTD: Pt100, Pt500, Pt1000, Ni100
Thermocouple: J, K, T, E, R, S, B, N
Potentiometer: 500 Ω to 10 KΩ
Resistance: 1750 Ω

Output: 4-20 mA loop powered
Powered by the output loop

  • Only 6.2 mm wide
  • PC programmable configuration
  • Full 2-way isolation
  • Low cost
  • DIN rail mount without tools
  • Powered by 4-20 mA loop

  • CE logo  new  EX
K121
K121

Thermocouple to DC Isolated Transmitter


Field Configurable


K109TC

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Configurable Input
Input: Thermocouple: J, K, T, E, R, S, N, B

Field Configurable Output
Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS

UL Listed   CE logo 
K109TC
K109TC

100 Ω RTD to DC Isolated Transmitter


Field Configurable


K109PT

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Field Configurable Input
Input: One 100 Ω RTD, 385 Curve RTD, 2, 3, or 4 wire
–150 to 650°C, (–238 to 1202°F), 50°C min. span

Field Configurable Output
Output: 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA,
0-5 V, 1-5 V, 0-10 V, 10-0 V

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS

UL Listed   CE logo 
K107A
K109PT

RS-485 to RS-485 or
RS-232 to RS-485
Repeaters/Isolators/Amplifiers


K107A, K107B

Open Datasheet
Download Datasheet

Open Installation Manual
Open Installation Manual

Click to see ALL Seneca products

K107A RS-485 to RS-485
Data X: One RS-485 half duplex
Data Y: One RS-485 half duplex

K107B RS-232 to RS-485
Data X: One RS-232 half duplex
Data Y: One RS-485 half duplex

  • Only 6.2 mm wide
  • DIP switch configuration
  • Full 3-way isolation
  • Low cost
  • DIN rail mount without tools
  • Power: 19.2-30 VDC or K-SUPPLY+KBUS

UL Listed   CE logo 
K107A K107B
K107A            K107B

USB - UART TTL Converter


EASY-USB

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

EASY-USB Software Link

Programming kitK121
K121

Includes
Converter
Software mini CD (or download latest)
Adapter cable (std USB cable not included)
EASY-USB
EASY-USB

K-SUPPLY and KBUS Power Supply
for K-Series Modules


K-SUPPLY, KBUS

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Regulated Power Distribution
Input: 19.2 to 30 VDC
Output: 19.2 to 30 VDC

  • Only 6.2 mm wide
  • Power supply distribution
  • Regulated and isolated
  • Low cost
  • DIN rail mount without tools
  • Power: any 19.2-30 VDC supply

CE logo
K107A
K-SUPPLY                 K-BUS

4 Digit 4-20 mA Loop Powered Display


Field Rangeable


S315
S315-IP66

Open Datasheet
Download Datasheet

Open Installation Manual
Download Installation Manual

Click to see ALL Seneca products

Loop Powered Display
Input: 4-20 mA
Display: 4 digit red LED

  • 1/8 DIN panel mount or IP66 housing
  • Scaleable 4 digit display

CE logo  new!
S315
S315