API Absolute Process Instruments, Inc.
Signal Conditioners, Signal Isolators, Process Transmitters
800-942-0315
Solutions and Support
You Can Depend On!
API modules Cecomp Gauges API-Camille Bauer APCS RheinTacho
DC Input Signal Conditioners & Transmitters
Links to similar models lifetime warranty Signal Splitters
DC Input Math & Square Root Modules
DC Input Alarms
4-20 mA Loop Isolators
DC Power Supplies
Reference Info pdf
Ground Loops
RFI / EMI
Application Examples
pdf
Monitoring Motor Speed Using a PLC
Building Heat SCR Control
Manual Override of Computer Control
Monitor Pressure with a PLC
Control & Monitor with One Flow Meter
Monitor Product Moved by Conveyor
Pharmaceutical Process Validation
Model Input Output Features
pdf APD 2000

DuoPak®
Two Channel Isolated Transmitter


New
Specify input range for each channel

Factory configured
DC voltage or current

These versions coming soon, call for availability
AC voltage or current
RTD
Frequency
Potentiometer
Strain gauge

Specify output range for each channel

Factory configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA

Others available
  • Two independent channels
  • I/O LoopTracker LEDs
  • Output test buttons
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount
  • 45 mm wide
  • Universal power 60-265 VAC, 85-300 VDC
  • D for 9-30 VDC, 10-32 VAC power
DuoPak
pdf API 4300 G

Isolated DC-DC Transmitter
with Loop Power Supply
Specify input range
Factory configured
0-100 mVDC to 0-100 VDC
±100 mVDC to ±10 VDC
0-1 mADC to 0-900 mADC
Others available
Specify output range
Factory configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
  • Hot-swappable plug-in design
  • Direct replacement for Action AP 4300
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • 18 V loop power supply
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC (+$60)
UL listed

Api 4300G
pdf APD 4300
APD 4300 PLC


Factory Ranged
Isolated DC-DC Transmitter
with I/O Loop Power Supplies

APD 4300 PLC is pre-configured for 4-20 mA I/O
  • Isolate single-ended iInputs, eliminate PLC/DCS ground loops
  • Isolate and correct sink-sink or source-source mismatches
  • Use with Allen Bradley, GE/Fanuc, IDEC, Omron, Mitsubishi, Modicon, Siemens, Panasonic, Honeywell analog inputs
Specify input range
Factory configured
0-100 mVDC to
0-100 VDC
±100 mVDC to ±10 VDC
0-1 mADC to
0-900 mADC
4-20 mA input

Others available

Milliamp input can be field wired for sink or source
new product
Specify output range
Factory configured
0-1 V to ±10 VDC,
0-1 mA to 4-20 mA,
up to 20 VDC with M09 option,
4-20 mA Output

Others available

Milliamp output can be field wired for sink or source

  • Removable plugs
  • I/O LoopTracker LEDs
  • Output test button
  • Output test terminals for manual override capability
  • Full I/O/power isolation
  • Selectable I/O sink/source
  • 15 V input loop power supply
  • 20 V output loop power supply
  • Universal power 60-265 VAC, 85-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power
APD 4300
pdf API 4310 G

Isolated DC-DC Transmitter
Narrow Input Span
with Loop Power Supply
Specify input range
Factory configured
0-10 mVDC to
0-100 mVDC
±50 mVDC
0-10 0 μADC to
0-1 mADC
Others available
Specify output range
Factory configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
  • Hot-swappable plug-in design
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • 18 V loop power supply
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC (+$60)
UL listed

Api 4310 G
pdf API 4380 G

Field Selectable Minuteman Setup

Isolated DC-DC Transmitter
with Loop Power Supply
24 Field configurable inputs
0-50 mVDC to
±10 VDC
0-1 mADC to
0-20 mADC
Others available
16 Field configurable outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
  • Minuteman one-minute setup
  • Hot-swappable plug-in design
  • Plug-in replacement for Action AP 4380 and Wilkerson Instruments MM 4380
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • 18 V loop power supply
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC power (+$60)
UL listed

Api 4380G
pdf API 4380 GHV3

Field Selectable Minuteman Setup

Isolated DC-DC Transmitter
High Voltage Input
24 field configurable inputs
0-1 VDC to
±200 VDC
Others available
16 field configurable outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
  • Minuteman one-minute setup
  • Hot-swappable plug-in design
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Uses API-008 8-Pin Socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC power (+$60)
UL listed
Api 4380 GHV
pdf APD 4380

Field Selectable Minuteman Setup

Isolated DC-DC Transmitter

New
53 field configurable input ranges
0-10 mVDC to 0-50 VDC
±10 mV to ±10 VDC
0-200 μA to 0-50 mADC
Others available
18 Field configurable output ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
Others available
  • One-minute setup
  • Removable plugs
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Selectable I/O sink/source
  • 15 V input loop power supply
  • 20 V output loop power supply
  • Universal power 60-265 VAC, 85-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power
APD4380
pdf API 4385 G

Field Selectable Minuteman Setup

Isolated DC-DC Transmitter
Wide Ranging with Input Offset
with Loop Power Supply
24 field configurable inputs
0-50 mVDC to
0-20 VDC
0-200 μADC to
0-40 mADC
Others available
Selectable zero offset
16 field configurable outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
  • Minuteman one-minute setup
  • Hot-swappable plug-in design
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • 18 V Loop Power Supply
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC power (+$60)
UL listed
Api 4385G
pdf APD HV-DC

Fast Field Selectable Setup
Isolated DC-DC Transmitter for
High Voltage DC Inputs

new product
8 Field configurable input ranges
7 standard plus 1 factory set custom range (specify if required)

0-100 VDC,
0-200 VDC,
0-300 VDC,
0-400 VDC,
0-500 VDC,
0-1000 VDC,
0-1200 VDC,
custom
18 Field configurable output ranges

0-1 V,
0-2 V,
0-4 V,
1-5 V,
0-5 V,
0-8 V,
2-10 V,
0-10 V,
±5 V,
±10 V,
0-2 mA,
0-4 mA,
0-8 mA,
2-10 mA,
0-10 mA,
0-16 mA,
4-20 mA,
0-20 mA
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • DIN rail mount
  • 22.5 mm wide
  • Universal power 60-265 VAC, 85-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power
APD HV-DC
pdf APD 4393

IsoSplitter DC-DC Signal Isolator-Splitter
New
Specify input range

Factory configured
0-10mVDC to 100 VDC,
±50 mV to ±10 VDC,
0-1 mADC to 0-50 mADC,
4-20 mADC

Current input may be
selectively wired for
sinking or sourcing
using built-in 15 VDC
power supply
Ch.1: Specify output range
Ch.2: Specify output range


Factory configured
2 Independent channels
0-1 VDC to 10 VDC,
±1 V to ±10 VDC,
0-1 mADC to 0-25 mADC,
4-20 mADC

Current outputs may be selectively wired for sinking or sourcing using built-in 20 VDC power supply.

Optional I/O reversal
Optional high voltage output to 20 VDC
  • Removable plugs
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • DIN rail mount
  • 45 mm wide
  • Universal power 60-265 VAC, 85-300 VDC
  • D option for 9-30 VAC/VDC power
Api 4393 DIN

pdf API 4400 G - API 4408 G   Specify input ranges
Factory configured
Input negative is common
0-1 V
0-5 V
1-5 V
0-10 V
±5 V
±10 V
0-20 mA
4-20 mA
Others available from 100 mV to 10 VDC
Specify output range
Factory configured
Others available
0-1 V
0-5 V
1-5 V
0-10 V
±5 V
±10 V
0-1 mA
0-20 mA
4-20 mA

Isolated DC output
  • Hot-swappable plug-in design
  • Direct replacements for Action AP 4400 series
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC power (+$60)


Api 4400G
API 4400 G: (A+B+C+D)/4
API 4401 G: (A+B+C)/3
API 4402 G: (A+B)/2
API 4403 G: (A+B+C–D)/3
API 4404 G: (A+B–C–D)/2
API 4405 G:  A–B–C–D
API 4406 G: (A+B–C)/2
API 4407 G:  A–B–C
API 4408 G:  A–B
pdf API 4440 G

DC to DC Transmitter with
Square Root Extraction
Specify input range
Factory configured
0-50 mVDC to
0-200 VDC
0-1 mADC to
0-50 mADC
Specify output range
Factory configured
Others available
0-1 V
0-5 V
1-5 V
0-10 V
±5 V
±10 V
0-1 mA
0-20 mA
4-20 mA
  • Hot-swappable plug-in design
  • Direct replacement for Action AP 4440
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • 18V loop power supply
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC power (+$60)
UL listed

Api 4440G
Documents for Discontinued Products
pdf API 4300 DIN,
API 4300 DD
DC-DC Transmitter. See APD 4300 above.
pdf API 4300 DIN PLC,
API 4300 DD PLC
4-20 mA DC-DC Transmitter. See APD 4300 PLC above.
pdf API 4380 DIN,
API 4380 DD
DC-DC Transmitter. See APD 4380 above.
pdf API DPI HV-DC High Voltage DC-DC Transmitter. See APD HV-DC above
pdf API 4010 G Non-Isolated DC-DC Transmitter with Loop Power Supply. See API 4300 G.
pdf API 4050 G Non-Isolated DC-DC Transmitter Narrow Input Span with Loop Power Supply. See API 4310 G
pdf API 4390 DIN,
API 4391 DIN,
API 4392 DIN
2 Channel DC-DC Transmitter Isolators. See APD 2000.
pdf API 4393 DIN G IsoSplitter DC-DC Signal Isolator-Splitter. See APD 4393.
Phone:  800-942-0315 or 847-918-3510 Fax:  800-949-7502 or 847-968-4891
APi Home Page
Copyright © 1999-2012 Absolute Process Instruments, Inc.