ThermoPro RTD Temperature Indicators, Alarms, and Transmitters

  • 1 Year Warranty
  • Fixed Probe or
    Spring Loaded for Thermowells
  • Lengths: 2.5", 4", 6", 9", 12"
  • Zero and Span Calibration




Click on model numbers below
for data sheets
Literature and Links

API product brochure

Reference Info

RFI / EMI

Relay Protection & EMI Suppression

How to Order
  1. Select a model
  2. See data sheet for ordering info and power options
  3. See Price list
  4. 2 day to 4 week typical lead time (USA customers)
  5. To place your order
Model Input/Output Features Product
ThermoPro®
Battery Powered RTD Temperature Indicator


T16B

T16BBL: Backlit display
  • Specify RTD length
  • Specify fixed or spring-loaded RTD
  • Use spring-loaded for a thermowell
  • Specify default temperature units
    • –58.0°F to 392.0°F or
    • –50.0°C to 200.0°C or
    • 223.0 K to 473.0 K
  • Choose auto shutoff time
    • -5 five minutes (default if not specified)
    • -10 ten minutes
    • -30 thirty minutes
    • -ON on/off only
  • See data sheet for complete model numbers
  • Battery life to 1000 hrs
  • BL red LED display backlight battery life up to 750 hrs
  • Includes 2 AA batteries
  • Configurable auto shutoff time
  • Selectable °F, °C or K
  • Selectable auto shutoff time
  • Configurable min/max memory
  • Able to retain min/max if power is off
  • Pass code protected setup and calibration

ThermoPro battery powered
T16B

ThermoPro®
Loop Powered Indicating RTD Transmitter


T16L
  • Specify RTD length
  • Specify fixed or spring-loaded RTD
  • Use spring-loaded for a thermowell
  • Specify temperature range of output
    • –58.0°F to 392.0°F or
    • –50.0°C to 200.0°C or
    • 223.0 K to 473.0 K
  • See data sheet for complete model numbers
  • 2-wire design
  • Powered by 8-32 VDC 4-20 mA current loop
  • User-programmable 4-20 mA output range
  • Selectable °F, °C or K
  • Pass code protected setup and calibration
  • Old model number: F16LT

ThermoPro
T16L
ThermoPro®
Indicating RTD Temperature Alarms


T16ADA
T16ADABL: Backlit display
  • Specify RTD length
  • Specify fixed or spring-loaded RTD
  • Use spring-loaded for a thermowell
  • Specify default temperature units
    • –58.0°F to 392.0°F or
    • –50.0°C to 200.0°C or
    • 223.0 K to 473.0 K
  • See data sheet for complete model numbers
  • User-programmable alarms
    • User-programmable alarm logic
    • User-programmable setpoints
    • 2 SPDT relays
    • 1A@24 VDC, or 0.5A@115VAC, non-inductive
  • Selectable °F, °C, or K temperature units
  • Powered by 8-32 VDC, 10-32 VAC
  • User configurable relay operation
  • Push to test alarms
  • Pass code protected setup and calibration

ThermoPro alarm
T16ADA