Signal Conditioner Accessories

S315 and S315-IP66
4 Digit 4-20 mA Loop Powered Display

1/8 DIN

S315 and S315 datasheet

S315 and S315 installation
Loop Powered Display
Input: 4-20 mA
Display: 4 digit red LED

  • 1/8 DIN panel mount or IP66 housing
  • 4-20 mA scalable to any 4 digit engineering units

CE logo 
S315
S315



Sockets

API 008
API 008 FS
API 011
API 011 FS


API 008: 8 pin socket
API 008 FS: 8 pin socket, finger-safe
API 011: 11 pin socket
API 011 FS: 11 pin socket
  • Sockets can be DIN rail or surface mounted
  • API 008 rated to 600V
  • All others rated to 300V
  • Mount with keyway down

API 008 API 008FS API 011 API 011FS
API 008     API 008 FS            API 011             API 011 FS

UL listed component CSA CE
Hold Down Spring

API CLP1

Hold-down spring for plug in modules
  • Works with any plug in module
  • For mobile applications
  • For high vibration applications

Api hold down spring
API CLP1
Current Shunts

API 008-5A
API 011-5A

API 008-5A: 8 pin socket,
with 5 A shunt, 0.1 Ohm, 1%, 25W

API 011-5A: 11 pin socket,
with 5 A shunt 0.1 Ohm, 1%, 25W
  • 5A option
  • For plug in modules
  • 0-5 Amp input
  • Module input must be set to mV
  • DIN rail or surface mount
  • See data sheets for applicable plug in modules

Api shunt base
API 008-5A

Signal Conditioner Options

Power API Plug In Module Operating Power Options
Standard Isolated 115 VAC module operating power
A230 Isolated 230 VAC optional module operating power
P Isolated 60-265 VAC or 85-300 VDC optional module operating power
D Isolated 9-30 VDC optional module operating power
Power APD DIN Rail Module Operating Power Options
Standard Isolated 60-265 VAC or 85-300 VDC module operating power
D Isolated 9-30 VDC, 10-32 VAC optional module operating power
Alarm Add Option Code to End of Model Number. See Data Sheet for Availability.
A Adjustable deadbands on dual alarms
HT Latching alarm with pushbutton reset for modules with single alarm
HP Latching alarm with power-off reset for modules with single alarm
R Reverse-acting alarms (non-failsafe)
L Low trip for single alarm modules (trip on decreasing signal)
HH High/High trip for dual alarm modules instead of High/Low
LL Low/Low trip for dual alarm modules instead of High/Low
Module Add Option Code to End of Model Number. See Data Sheet for Availability.
B Downscale burnout for thermocouple modules (upscale standard)
DF Fast response time, available on many models, consult factory
U Conformal coating on circuit boards for moisture resistance