API Absolute Process Instruments, Inc.
Signal Conditioners, Signal Isolators, Process Transmitters
800-942-0315
Solutions and Support
You Can Depend On!
API modules Cecomp Gauges API-Camille Bauer APCS RheinTacho
DC Input Alarms
Click on model numbers below for product data sheets lifetime warranty LoopTracker® LED
Alarm Status LEDs
Push to Test/Reset Alarms
Lifetime Warranty
Reference Info pdf
Alarm Terminology
Deadband
Relay Protection & EMI Suppression
Model Input Output Features
pdf API 1000 G

DC Input
Single Alarm Trip
Specify input range
Factory configured
0-100 mVDC to
0-300 VDC
0-1 mADC to
0-900 mADC

With 5A shunt option
0-900 mADC to 0-5 ADC
One DPDT 7A contact set
Field adjustable setpoint
Specify alarm type
See data sheet for alarm options
  • Hot-swappable plug-in design
  • Direct replacement for Action AP 1000 and AP 1020
  • LoopTracker LED for input
  • Alarm status LEDs
  • Output test button
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power(+$60)
  • D option for 9-30 VDC power (+$60)

Api 1000 G
pdf API 1020 G

DC Input
Dual Alarm Trip
Two SPDT 7A contact sets
Field adjustable setpoints
Specify alarm type
See data sheet for alarm options
pdf APD 1000

DC Input
Single Alarm Trip
Specify input range
Factory configured
0-100 mVDC to
0-300 VDC
0-1 mADC to
0-20 mADC,
4-20 mA
Single setpoint dual SPDT Form C contact sets
Field adjustable setpoint
Specify alarm type
Factory configured
Standard: HI alarm, non-latching, normal acting
Options: LO alarm, latching, reverse acting
  • DIN rail mount without tools
  • Removable plugs
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm test button
  • Full I/O/power isolation
  • Selectable input sink/source
  • 15 V input loop power supply
  • Universal power 60-265 VAC, 85-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power
New!
APD 1000
pdf APD 1020

DC Input
Dual Alarm Trip
2 independent setpoint SPDT Form C contact sets
Field adjustable setpoints
Specify alarm type
Factory configured
Standard: HI/LO alarm, non-latching, normal acting
Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting
pdf APD 1030

DC Input
Band Alarm Trip
2 independent setpoint SPDT Form C contact sets
Field adjustable setpoints
Specify alarm type
Factory configured
Standard: Band alarm (both alarms trip if outside LO and HI trip points), non-latching, normal acting
Options: Inverse band alarm, latching, reverse acting
pdf API 1005 G

4-20 mA Input Single Alarm Trip with Loop Power Supply
Factory configured
4-20 mADC
One DPDT 7A contact set
Field adjustable setpoint
Specify Alarm Type
See data sheet for alarm options
  • Hot-swappable plug-in design
  • LoopTracker LED for input
  • Alarm status LEDs
  • Output test/alarm reset button
  • 18 V loop power supply
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power(+$60)
  • D option for 9-30 VDC power (+$60)

Api 1005G
pdf API 1025 G

4-20 mA Input Dual Alarm Trip with Loop Power Supply
Two SPDT 7A contact sets
Field adjustable setpoints
Specify alarm type
See data sheet for alarm options
pdf API 1040 G

DC Input Single Alarm Trip
with DC-DC Transmitter (Non-Isolated)
and Loop Power Supply
Specify input range
Factory configured
0-100 mVDC to
0-200 VDC
±100 mVDC to ±10 VDC
0-1 mADC to
0-50 mADC
One SPDT 7A contact set
Field adjustable setpoint
Specify alarm type
See data sheet for alarm options

Specify transmitter output range
Factory configured output
0-1 V, 0-5 V, 1-5 V, 0-10 V,
±5 V, ±10 V,
0-20 mA, 4-20 mA
others available
  • Hot-swappable plug-in design
  • LoopTracker LED
  • Alarm status LEDs
  • Output test/alarm rReset button
  • 18 V loop power supply
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power(+$60)
  • D option for 9-30 VDC power (+$60)

Api 1040 G
pdf API 1080 G

Field Selectable Minuteman Setup

DC Input Single Alarm Trip
Input Loop Power Supply
24 field configurable input ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC
Field configurable alarm

One DPDT 7A contact set

Adjustable setpoint
  • Minuteman one-minute setup
  • Hot-swappable plug-in design
  • LoopTracker LED
  • Alarm status LED
  • Output test/alarm reset button
  • 18 V loop power supply
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC power (+$60)

Api 1080 G
Socket sold separately
pdf APD 1080

Fast Field Selectable Setup

DC Input Single Dual DPST Alarm Trip
Input Loop Power Supply


New!
24 Field Configurable Input Ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC

mA input can be wired for sink or source
Field configurable alarm

Two DPST 8A contact sets

One adjustable setpoint with deadband

2 form A (NO) contact sets

2 form B (NC) contact sets

May be field wired for form C operation
  • One-minute setup
  • Removable plugs
  • Input LoopTracker LED
  • Alarm status LED
  • Alarm test button
  • Full I/O/power isolation
  • Selectable input sink/source
  • 15 V input loop power supply
  • Universal power 60-265 VAC, 85-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power
APD1080

pdf API 1090 G

Field Selectable Minuteman Setup

DC Input Dual Alarm Trip
Input Loop Power Supply

26 field configurable input ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC
Field configurable alarms

Two SPDT 7A contact sets

Adjustable setpoints
  • Minuteman one-minute setup
  • Hot-swappable plug-in design
  • LoopTracker LED
  • Alarm status LEDs
  • Output test/alarm reset button
  • 18 V loop power supply
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 60-265 VAC, 85-300 VDC power (+$60)
  • D option for 9-30 VDC power (+$60)

Api 1090 G
Socket sold separately
pdf APD 1090

Fast Field Selectable Setup

DC Input Alarm Trip
Two Independent DPST Relay
Input Loop Power Supply


New!
24 field configurable input ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC
mA input can be wired for sink or source
Field configurable alarms

Two DPST 8A contact sets

Two adjustable setpoints each with deadband

SP 1: form A (NO) and form B (NC) contacts

SP 2: form A (NO) and form B (NC) contacts (4 terminals)

May be field wired for form C operation
  • One-minute setup
  • Removable plugs
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm test button
  • Full I/O/power isolation
  • Selectable input sink/source
  • 15 V input loop power supply
  • Universal power 60-265 VAC, 85-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power
APD 1090
Documents for Discontinued Products
pdf API 1080 DIN DC Input Single Alarm Trip. See APD 1080 above
pdf API 1090 DIN
API 1090 DD
DC Input Dual Alarm Trip. See APD 1090 above
Phone:  800-942-0315 or 847-918-3510 Fax:  800-949-7502 or 847-968-4891
APi Home Page
Copyright © 1999-2012 Absolute Process Instruments, Inc.