| DC Input Alarms | ||||
|---|---|---|---|---|
Click on model numbers below for product data sheets
|
LoopTracker® LED Alarm Status LEDs Push to Test/Reset Alarms Lifetime Warranty |
Reference Info ![]() Alarm Terminology Deadband Relay Protection & EMI Suppression |
||
| Model | Input | Output | Features | |
API 1000 GDC Input Single Alarm Trip |
Specify input range Factory configured 0-100 mVDC to 0-300 VDC 0-1 mADC to 0-900 mADC With 5A shunt option 0-900 mADC to 0-5 ADC |
One DPDT 7A contact set Field adjustable setpoint Specify alarm type See data sheet for alarm options |
|
|
API 1020 GDC Input Dual Alarm Trip |
Two SPDT 7A contact sets Field adjustable setpoints Specify alarm type See data sheet for alarm options |
|||
APD 1000DC Input Single Alarm Trip |
Specify input range Factory configured 0-100 mVDC to 0-300 VDC 0-1 mADC to 0-20 mADC, 4-20 mA |
Single setpoint dual SPDT Form C contact sets Field adjustable setpoint Specify alarm type Factory configured Standard: HI alarm, non-latching, normal acting Options: LO alarm, latching, reverse acting |
|
![]()
|
APD 1020DC Input Dual Alarm Trip |
2 independent setpoint SPDT Form C contact sets Field adjustable setpoints Specify alarm type Factory configured Standard: HI/LO alarm, non-latching, normal acting Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting |
|||
APD 1030DC Input Band Alarm Trip |
2 independent setpoint SPDT Form C contact sets Field adjustable setpoints Specify alarm type Factory configured Standard: Band alarm (both alarms trip if outside LO and HI trip points), non-latching, normal acting Options: Inverse band alarm, latching, reverse acting |
|||
API 1005 G4-20 mA Input Single Alarm Trip with Loop Power Supply |
Factory configured 4-20 mADC |
One DPDT 7A contact set Field adjustable setpoint Specify Alarm Type See data sheet for alarm options |
|
![]() |
API 1025 G4-20 mA Input Dual Alarm Trip with Loop Power Supply |
Two SPDT 7A contact sets Field adjustable setpoints Specify alarm type See data sheet for alarm options |
|||
API 1040 G
DC Input Single Alarm Trip with DC-DC Transmitter (Non-Isolated) and Loop Power Supply |
Specify input range Factory configured 0-100 mVDC to 0-200 VDC ±100 mVDC to ±10 VDC 0-1 mADC to 0-50 mADC |
One SPDT 7A contact set Field adjustable setpoint Specify alarm type See data sheet for alarm options Specify transmitter output range Factory configured output 0-1 V, 0-5 V, 1-5 V, 0-10 V, ±5 V, ±10 V, 0-20 mA, 4-20 mA others available |
|
|
API 1080 GField Selectable Minuteman Setup DC Input Single Alarm Trip Input Loop Power Supply |
24 field configurable input ranges Min: 0-50 mVDC Max: ±10 VDC Min: 0-1 mADC Max: 0-20 mADC |
Field configurable alarm One DPDT 7A contact set Adjustable setpoint |
|
![]() Socket sold separately |
APD 1080
Fast Field Selectable Setup DC Input Single Dual DPST Alarm Trip Input Loop Power Supply
|
24 Field Configurable Input Ranges Min: 0-50 mVDC Max: ±10 VDC Min: 0-1 mADC Max: 0-20 mADC mA input can be wired for sink or source |
Field configurable alarm Two DPST 8A contact sets One adjustable setpoint with deadband 2 form A (NO) contact sets 2 form B (NC) contact sets May be field wired for form C operation |
|
![]() |
|
|
26 field configurable input ranges Min: 0-50 mVDC Max: ±10 VDC Min: 0-1 mADC Max: 0-20 mADC |
Field configurable alarms
Two SPDT 7A contact sets Adjustable setpoints |
|
![]() Socket sold separately |
APD 1090
Fast Field Selectable Setup DC Input Alarm Trip Two Independent DPST Relay Input Loop Power Supply
|
24 field configurable input ranges Min: 0-50 mVDC Max: ±10 VDC Min: 0-1 mADC Max: 0-20 mADC mA input can be wired for sink or source |
Field configurable alarms Two DPST 8A contact sets Two adjustable setpoints each with deadband SP 1: form A (NO) and form B (NC) contacts SP 2: form A (NO) and form B (NC) contacts (4 terminals) May be field wired for form C operation |
|
![]() |
| Documents for Discontinued Products | ||||
API 1080 DIN
|
DC Input Single Alarm Trip. See APD 1080 above | |||
API 1090 DINAPI 1090 DD |
DC Input Dual Alarm Trip. See APD 1090 above | |||