Electric Power Monitors and Transducers
Heavy current engineering

Internationally accepted Swiss precision for optimum energy management.

The deregulation of energy markets and globally increasing environmental awareness define a high degree of responsibility for companies to treat power as a precious resource. Camille Bauer provides a wide spectrum of innovative and highly efficient power measurement and analysis products.

Our extensive product line is manufactured in accordance with individual customer specifications and their functionality is adapted to your requirements in order to guarantee optimum results. Custom-made measuring performance has always been part of our service.

  • Sineax Power Products
  • Power Meters and Monitors
  • Power Analysis
  • Power Transducers
  • Sineax Software
Camille Bauer Industrial Catalog pdf
Camille Bauer Industrial Catalog
How to Order
  1. Select your model
  2. See data sheet for ordering info and options
  3. Call 800-942-0315 for ordering assistance and a quotation
  4. 3 to 4 week typical lead time (USA customers)
  5. To place your order
Model/Downloads Input/Output Features Product
Multi-Function Power Meters

DM5S, DM5F Universal Power Transducer with MODBUS Interface and/or Analog Outputs

DM5 Data Sheet
DM5 Instructions

MODBUS Basics
MODBUS Instructions
CB Manager Software
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz

Output: Up to 4 analog outputs and/or MODBUS interface

Programmable universal measurement devices for energy distribution and industrial applications. The devices can be quickly set up with CB-Manager software. Versions are availalbe for analog DC current outputs or Modbus. Measurements are done in all four quadrants and can be optimally adapted to the system to be monitored. Both the average time of the measurement and the expected maximum signal level can be configured. Commissioning is very easy and is supported by means of service functions, such as nameplate printing, connection check, measurement acquisition as well as simulation and trimming of the analog outputs.

  • DM5F: Fast response version
  • System state monitoring: class 0.2
  • Energy metering class 0.5S
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • USB PC programming interface
  • Configure using CB Manager software
  • 24-230 VDC or 100-230 VAC powered
DM5
profibus logo CE logo UL

Sineax CAM Multifunction Energy Transducer

CAM Brochure
Rogowski Sensors Brochure
CAM Data Sheet
CAM Instructions
CAM Instructions for Graphic Display
CAM Safety Instructions

CAM Installation of IEC 61850 option
CAM IEC 61850 Certificate

CB Manager Software
CB Data Analylysis Software
CAM ICD Files
MODBUS Basics
MODBUS Instructions
MODBUS/TCP Instructions
Input: 0-1A, 0-5 A from CT or Two 4-20 mA, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz, Digital I/O

Output/Communications: RS-485 MODBUS, Relay, Up to 4 analog, Digital I/O, USB 2.0 programming interface
  • True RMS
  • Simultaneous measurement of all 3 phases
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, LF, f, THD, TDD, VAR
  • 85-265 VAC/ 110-265 VDC powered
  • Optional 17-90 VDC powered
CAM
CAM with display
Modbus

IEC 61850

  CE logo

Sineax A200 Multifunction Display for DME Power Transducers

Data Sheet
Instructions
DIN Rail Adapter
Input: Serial data from DME4 series

Output: 3 digital displays
  • 1/4 DIN (96 x 96 mm) display for DME4 transducers
  • Triple LED display 14 mm digit height
  • Selectable display parameters
  • 20-265 VAC/VDC powered
A200 CE logo Din bracket
Power Transducers

Sineax P 530 Active Power & Q 531 Reactive Power Transducers

Data Sheet
Instructions, Single Phase Models
Instructions, 3-Phase Models
CSA Certificate
GL Certificate for Shipboard Use, 3-Phase Version
Input: 0-0.8 A to 0-1.2 A or, 0-4 A to 0-6 A, 100-690 V, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • 3-Phase with Balanced or Unbalanced Load
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
P 530

CE logo  CSA logo  Germanischer Lloyd
Current Transducers

Sineax I 538 AC Current Transducer

Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
I 538

CE logo  CSA logo  Germanischer Lloyd

Sineax I 542 AC Current Transmitter

Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Powered from Measuring Source
I 542

CE logo  CSA logo  Germanischer Lloyd

Sineax I 552 True RMS AC Current Transducer

Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT , 50/60 or 400 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
I 552

CE logo  CSA logo  Germanischer Lloyd
Voltage Transducers

Sineax U 539 AC Voltage Transducer

Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 0-50 V to 0-600 V, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
U 539

CE logo  CSA logo  Germanischer Lloyd

Sineax U 543 AC Voltage Transducer

Data Sheet
Instructions
CE Declaration
CSA Certificate
GL Certificate for Shipboard Use
Input: 0-20 V to 0-600 V, 50/60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Powered from Measuring Source
U 543

CE logo  CSA logo  Germanischer Lloyd

Sineax U 553 True RMS AC Voltage Transducer

Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 0-20 V to 0-690 V, 50/60 or 400 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sine, Rectangular or Distorted Wave Forms
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
U 553

CE logo  CSA logo  Germanischer Lloyd

Sineax U 554 True RMS AC Voltage Transducer

Data Sheet
Instructions
Input: 0-20 V to 0-690 V, 50/60 or 400 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Special Version to Allow Zero Offset
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
U 554

CE logo



Frequency Transducers

Sineax F 534 Frequency Transducer

Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 10 V to 690 V, 10 to 1500 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, to ±10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
F 534

CE logo  CSA logo  Germanischer Lloyd

Sineax F 535 Frequency Difference Transducer

Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 10 V to 690 V, 10 to 1500 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, to ±10 V
  • Measure Δf Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
F 535

CE logo  CSA logo  Germanischer Lloyd
Phase Angle (Power Factor) Transducers

Sineax G 536 Phase Angle Transducer

Data Sheet
Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 1 or 5 A from CT, 10 V to 690 V, 16 to 400 Hz, 0.5 cap. 1.ind. 0.5 cos Φ

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • Measure Single or 3-Phase Balanced
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
g 536

CE logo  CSA logo  Germanischer Lloyd

Sineax G 537 Phase Angle Difference Transducer

Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 10 V to 690 V, 50 or 60 Hz

Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • Measure ΔΦ Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
G 537

CE logo  CSA logo  Germanischer Lloyd