| Absolute Process Instruments, Inc. Signal Conditioners, Signal Isolators, Process Transmitters 800-942-0315 |
Solutions and Support You Can Depend On! |
|||
![]() |
![]() |
![]() |
![]() |
![]() |
|
|
||||
| Strain Gauge, Bridge, Pressure Transducer, and Load Cell Alarms, Signal Conditioners and Transmitters | ||||
|---|---|---|---|---|
Click on model numbers below for data sheets
|
Reference Info ![]() Alarm Terminology Deadband Relay Protection & EMI Suppression Troubleshooting Strain Gauge Type Sensors Application Examples ![]() Chemical Plant Platform Scale Truck Scale Dispensing System Automation 6-Wire Strain Gauges Pressure Sensor vs. Pressure Transmitter Plastics Extruder Melt Pressure Pressure System Calibration Pressure Transducer Calibration |
|||
| Model | Input | Output | Features | |
API 4051 G IBridge to DC Transmitter Isolated |
Specify input range Factory configured Others available 1 mV/V 2 mV/V 3 mV/V 5 mV/V 10 mV/V 20 mV/V 50 mV/V 100 mV/V 200 mV/V Specify excitation voltage 4 to 10 VDC |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-20 mA 4-20 mA |
|
|
API 4058 GField Selectable Minuteman Setup Bridge to DC Transmitter |
Field configurable 0-5 mVDC to 0-1200 mVDC Field settable excitation voltage |
18 Field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
|
API 4059 GField Selectable Minuteman Setup Isolated Bridge to DC Transmitter |
Field configurable 0-5mVDC to 0-400mVDC Field settable excitation voltage 0-10VDC in 1VDC steps |
18 field configurable outputs 0-1V to ±10V 0-2mA to 0-20mA 4-20mA |
|
![]() Socket sold separately |
APD 4059Field Selectable Minuteman Setup Isolated Bridge to DC Transmitter Isolated
|
Field configurable 0-5 mVDC to 0-400 mVDC Field settable excitation voltage 0-10 VDC in 1 VDC steps |
18 Field configurable outputs 0-1 V to ±1 0V 0-2 mA to 0-2 0mA 4-20 mA |
|
![]() |
APD 1500Strain Gauge Input Single Alarm Trip |
Specify strain gauge mV/V rating, mV range, excitation voltage Factory configured 100 Ω to 10000 Ω strain gauge 5 mV to 2000 mV 1-10 VDC excitation |
APD 1500 Field adjustable single setpoint alarm Dual 8A SPDT form C contact set See data sheet to specify alarm type Standard: HI alarm, non-latching, normal acting Options: LO alarm, latching, reverse acting |
|
![]()
|
APD 1520Strain Gauge Input Dual Alarm Trip |
APD 1520 Field adjustable 2 setpoint alarms Two 8A SPDT form C contact sets See data sheet to specify alarm type Standard: HI/LO alarm, non-latching, normal acting Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting |
|||
APD 1530Strain Gauge Input Band Alarm Trip |
APD 1530 Field adjustable 2 setpoint band alarm Two 8A SPDT form C contact sets See data sheet to specify alarm type Standard: Band alarm (both alarms trip if outside LO and HI trip points), non-latching, normal acting Options: Inverse band alarm, latching, reverse acting |
|||
| Documents for Discontinued Products | ||||
API 1500 G, 1520 G |
Bridge Input Single Alarm Trip. See APD 1500 series. | |||
API 4051 G
|
Bridge to DC Transmitter, Non-isolated. Use API 4051 GI. | |||
API 4059 DIN |
Isolated Bridge to DC Transmitter. See APD 4059. | |||
API SUM-000,API SUM-025 |
Bridge Summing Board. Call for replacement. | |||
API SUM Board Instruction Manual |
Bridge Summing Board Detailed Instructions | |||
| Phone: 800-942-0315 or 847-918-3510 | Fax: 800-949-7502 or 847-968-4891 | |
| APi Home Page Copyright © 1999-2012 Absolute Process Instruments, Inc. |
||