| RTD Temperature Products | ||||
|---|---|---|---|---|
Click on model numbers below for product data sheets
|
LoopTracker® LEDs Easy Plug-In Design Hot-Swappable Output Test Lifetime Warranty |
|||
| Model | Input | Output | Features | |
APD 1400RTD Input Single Alarm Trip |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or special |
APD 1400 Field adjustable single setpoint alarm Dual 8A SPDT form C contact set See data sheet to specify alarm type Standard: HI alarm, non-latching, normal acting Options: LO alarm, latching, reverse acting |
|
![]()
|
APD 1420RTD Input Dual Alarm Trip |
APD 1420 Field adjustable 2 setpoint alarms Two 8A SPDT form C contact sets See data sheet to specify alarm type Standard: HI/LO alarm, non-latching, normal acting Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting |
|||
APD 1430RTD Input Band Alarm Trip |
APD 1430 Field adjustable 2 setpoint band alarm Two 8A SPDT form C contact sets See data sheet to specify alarm type Standard: Band alarm (both alarms trip if outside LO and HI trip points), non-latching, normal acting Options: Inverse band alarm, latching, reverse acting |
|||
API 1400 GRTD Input Single Alarm Trip |
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or Special |
1 DPDT 7A contact set Field adjustable Specify alarm type See data sheet for alarm options |
|
|
API 1420 GRTD Input Dual Alarm Trip |
2 SPDT 7A contact sets Field adjustable Specify alarm type See data sheet for alarm options |
|||
APD 4001Isolated & Linearized RTD Temperature to DC Transmitter |
Specify RTD type and temperature range Factory configured 10 Ω Copper 100 Ω 0.00385α 100 Ω 0.00391α 2000 Ω Ni-Fe Popular ranges Also available in °C –100-300°F 0-300°F 0-400°F 0-500°F 0-600°F 0-1000°F 0-1500°F |
Specify output range Factory configured Others available Typical ranges 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
|
API 4001 G LIsolated & Linearized RTD Temperature to DC Transmitter |
Specify RTD type and temperature range Factory configured 10 Ω Copper 100 Ω 0.00385α 100 Ω 0.00391α 2000 Ω Ni-Fe Also available in °C –100-300°F 0-300°F 0-400°F 0-500°F 0-600°F 0-1000°F 0-1500°F |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
|
API 4001 G SA-BDifferential RTD Temperature to DC Transmitter Non-Isolated |
Specify temperature range Factory configured ΔT from 20F° to 900F° or 10C° to 500C° Two 100 Ω 0.00385α RTDs |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-20 mA 4-20 mA |
|
|
Sineax V624Programmable Isolated RTD or T/C to DC Transmitter Microprocessor-Based |
T/C types J, K, T, E, R, S, N, B, W5, W3, L, U RTD 2-, 3-, or 4-wire 100 Ω 0.00385α 100 Ω 0.003916α Thermistor Custom |
Specify if Current or Voltage Output 0-2 mA to 0-20 mA, 20-0 mA, 0-1 V to 0-10 V, 10-0 V |
InstructionsSoftware |
![]()
|
APD 1393IsoSplitter® RTD Input to Two DC Outputs
|
Specify RTD type and temperature range Factory configured 10 Ω to 2000 Ω RTD including 100 Ω 0.00385α 100 Ω 0.00391α, 10 Ω Cu, 1000 Ω Ni-Fe, 120 Ω Ni or special |
Specify DC output range for each channel Factory configured 0-1 V, 0-5 V, 1-5 V, 0-10 V ±5 V, ±10 V 0-1 mA, 0-20 mA, 4-20 mA Others available |
|
|
T16B SeriesThermoPro Battery Powered RTD Temperature Indicator ![]() |
Specify RTD Length and Fixed or Spring-Loaded RTD Temperature range –58.0°F to 392.0°F or –50.0°C to 200.0°C Selectable °F or °C See data sheet for model numbers |
None, indicator only |
|
![]() |
T16L Series(F16LT) ThermoPro® Indicating RTD Transmitter |
Specify RTD Length and Fixed or Spring-Loaded RTD Temperature range –58.0°F to 392.0°F or –50.0°C to 200.0°C Selectable °F or °C See data sheet for model numbers |
4-20 mA output is user configurable over the temperature range |
|
![]() |
T16ADA SeriesThermoPro® Indicating RTD Temperature Alarm ![]() |
Specify RTD Length and Fixed or Spring-Loaded RTD Temperature range –58.0°F to 392.0°F or –50.0°C to 200.0°C Selectable °F or °C See data sheet for model numbers |
2 SPDT relays, 1 A @ 24 VDC, 0.5 A @ 115 VAC, Non-inductive, Fully programmable |
|
![]() |
| Documents for Discontinued Products | ||||
API 4000 G |
RTD or T/C to DC Transmitter. Replaced by the Sineax V624 | |||
API 4100 G |
Non-Isolated T/C-DC Transmitter. Replaced by the API 4130 GL | |||