| Absolute Process Instruments, Inc. Signal Conditioners, Signal Isolators, Process Transmitters 800-942-0315 |
Solutions and Support You Can Depend On! |
|||
![]() |
![]() |
![]() |
![]() |
![]() |
|
|
||||
| Frequency Alarms, Signal Conditioners, and Frequency I/O Transmitters | ||||
|---|---|---|---|---|
Click on model number below for data sheet
![]() Lifetime warranty on API modules |
Reference Info ![]() Alarm Terminology Deadband Relay Protection & EMI Suppression RFI / EMI Application Examples ![]() Remote Monitoring of Motor Speed HVAC Variable Air Volume Control Hall-Effect Flow Sensor Auto-Ranging Flow Meter Control and Record Water Flow Monitoring & Totalizing Flow Monitoring & Totalizing Flow Meter Output Diesel Application |
|||
| Model | Input | Output | Features | |
API 1700 GFrequency Input Single Alarm Trip |
Specify input range Factory configured Minimum: 10 Hz Maximum: 20 kHz 100 mV to 150 V RMS |
1 DPDT 7A contact set Field adjustable Specify alarm type See data sheet for alarm options |
|
s |
API 1720 GFrequency Input Dual Alarm Trip |
Specify input range Factory configured Minimum: 10 Hz Maximum: 20 kHz 100 mV to 150 V RMS |
2 SPDT 7A Contact sets Field adjustable Specify alarm type See data sheet for alarm options |
||
API 7010 GFrequency to DC Transmitter Isolated |
Specify input range Factory configured Minimum: 25 Hz Maximum: 20 kHz 100mV to 150 V RMS |
Specify output range Factory configured Others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-2 0mA 4-20 mA |
|
|
APD 7010Frequency to DC Transmitter Isolated |
Specify input range Factory configured Minimum: 25 Hz Maximum: 20 kHz 100mV to 150 V RMS |
Specify output range Factory configured Popular ranges, others available 0-1 V 0-5 V 1-5 V 0-10 V ±5 V ±10 V 0-1 mA 0-20 mA 4-20 mA |
|
|
API 7500 GField Selectable Minuteman Setup DC to Frequency Transmitter Isolated |
24 field configurable inputs 0-50 mVDC to ±10 VDC 0-1 mADC to 0-20 mADC |
30 field configurable outputs Low range 100Hz increments Min: 0-100 Hz Max: 0-1500 Hz High range 2 kHz increments Min: 2 kHz Max: 30 kHz MOSFET output standard MO2 option for TTL output |
|
![]() Socket sold separately |
API 7500 G SSField Selectable Minuteman Setup DC to Low Frequency Transmitter Isolated |
24 field configurable inputs 0-50 mVDC to ±10 VDC 0-1 mADC to 0-20 mADC |
30 field configurable outputs Low range 1Hz increments Min: 0-1 Hz Max: 0-15 Hz High range 20 Hz increments Min: 20 Hz Max: 300 Hz MOSFET output standard |
|
![]() Socket sold separately |
APD 7580Field Selectable Minuteman Setup Frequency to DC Transmitter Isolated
|
30 field configurable inputs Low range 100 Hz increments Min: 0-100 Hz Max: 0-1500 Hz High range 2 kHz increments Min: 2 kHz Max: 30 kHz |
18 field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() |
API 7580 GField Selectable Minuteman Setup Frequency to DC Transmitter Isolated |
30 field configurable inputs Low range 100 Hz increments Min: 0-100 Hz Max: 0-1500 Hz High range 2 kHz increments Min: 2 kHz Max: 30 kHz |
16 field configurable outputs 0-1 V to ±10 V 0-2 mA to 0-20 mA 4-20 mA |
|
![]() Socket sold separately |
RheinTacho Speed MonitorsCR CRR CRA CRRA Field Programmable Isolated |
Programmable Min: 0-0.01 Hz Max: 0-20,000 Hz Optional sensors: Hall Differential Hall Magnetoresistive
See price list for standard sensors |
CR: 1 relay CRR: 2 relays CRA: 1 relay & analog output CRRA 2 relays & analog output Relay: 5A @ 250 VAC resistive or 2A @ 42 VDC resistive Analog output: 0-20mA or 4-20mA |
Instructions
|
![]() ![]() Sensors sold separately |
| Phone: 800-942-0315 or 847-918-3510 | Fax: 800-949-7502 or 847-968-4891 | |
| APi Home Page Copyright © 1999-2012 Absolute Process Instruments, Inc. |
||