AC Input Alarms
- 6 Year Warranty on API Modules
- LoopTracker® Input LED
- Alarm Status LEDs
- Hot-Swappable Plug-In Design
- User Adjustable Setpoint(s)
- Push to Test/Reset Alarms
- Full I/O/Power Isolation
Product brochure
Options & accessories
Cross reference
Regulatory compliance
Click on PDF links below
for product information
Alarm Terminology
Deadband
Relay Protection & EMI Suppression
RFI / EMI
Motor Load Current
Applications
Heater Break Alarm
Monitor Mold Heaters
Railroad Crossing Current Monitor
- Open pdf datasheet for your model
- Select model, range, units, options, accessories
- Contact us if you need assistance
Other ways to order
- Click here to set up an account
- Click here to find your authorized dealer or
if you are outside the USA - Call us to find your local authorized distributor
API Product Quick Ordering Specifications |
||||
|---|---|---|---|---|
|
Please specify Input, Output (and/or Alarm Settings) and Power on your order. No charge to setup standard ranges or alarm setpoints. Some configurations and DC power options are extra charge. |
||||
| DC Input Alarms | Replaces | Specify Input | Specify Output | Power |
| API 1000 G | Action AP1000 Wilkerson Instruments MM1000 |
DC voltage or current range |
Alarm type:
HI or LO (factory set) Setpoint & deadband: specify or field adjust |
115 VAC or specify |
| API 1005 G | Wilkerson Instruments MM1005 | 4-20 mA |
Alarm type:
HI or LO (factory set) Setpoint & deadband: specify or field adjust |
115 VAC or specify |
| API 1020 G | Action AP1020 Wilkerson Instruments MM1020 |
DC voltage or current range |
Alarm type:
H/L, H/H, L/L, L/H specify or internal jumper select Alarm action: normal Setpoints: specify or field adjust |
115 VAC or specify |
| API 1025 G | 4-20 mA |
Alarm type:
H/L, H/H, L/L, L/H specify or internal jumper select Alarm action: normal (factory set) Setpoints: specify or field adjust |
115 VAC or specify | |
| API 1080 G | Action AP1080 Wilkerson Instruments FR1000 |
DC voltage or current range or field select |
Alarm type:
H, L, norm/rev, latch/no latch (field configurable) Setpoint & deadband: specify or field adjust |
115 VAC or specify |
| APD 1080 | DC voltage or current range or field select | Alarm type:
H, L, norm/rev, latch/no latch (field configurable) Setpoint & deadband: specify or field adjust |
85-265 VAC or 60-300 VDC | |
| APD 1080 D | DC voltage or current range or field select |
Alarm type:
H, L, norm/rev, latch/no latch (field configurable) Setpoint & deadband: specify or field adjust |
9-30 VDC or 10-32 VAC |
|
| API 1090 G | Action AP1090 Wilkerson Instruments FR1020 |
DC voltage or current range or field select |
Alarm type:
H/L, H/H, L/L, L/H, norm/rev, latch/no latch (field configurable) Setpoints & deadbands: specify or field adjust |
115 VAC or specify |
| APD 1090 | DC voltage or current range or field select |
Alarm type:
H/L, H/H, L/L, L/H, norm/rev, latch/no latch (field configurable) Setpoints & deadbands: specify or field adjust |
85-265 VAC or 60-300 VDC | |
| APD 1090 D | DC voltage or current range or field select |
Alarm type:
H/L, H/H, L/L, L/H, norm/rev, latch/no latch (field configurable) Setpoints & deadbands: specify or field adjust |
9-30 VDC or 10-32 VAC |
|
| DC Input | Replaces | Specify Input | Specify Output | Power |
| API 4300 G | Action AP4300-xxxx Wilkerson Instruments MM4300 |
DC voltage or current range | DC voltage or current range | 115 VAC or specify |
| APD 4300 | Action AP4300-xxxx Wilkerson Instruments MM4300 |
DC voltage or current range | DC voltage or current range | 85-265 VAC or 60-300 VDC |
| APD 4300 D | DC voltage or current range | DC voltage or current range | 9-30 VDC or 10-32 VAC |
|
| API 4310 G | DC voltage or current range | DC voltage or current range | 115 VAC or specify | |
| API 4380 G | DC voltage or current range or field select | DC voltage or current range or field select | 115 VAC or specify | |
| API 4380 G DF | DC voltage or current range or field select | DC voltage or current range or field select | 115 VAC or specify | |
| API 4380 G HV | DC voltage or current range or field select | DC voltage or current range or field select | 115 VAC or specify | |
| APD 4380 | DC voltage or current range or field select | DC voltage or current range or field select | 85-265 VAC or 60-300 VDC | |
| APD 4380 D | DC voltage or current range or field select | DC voltage or current range or field select | 9-30 VDC or 10-32 VAC |
|
| API 4385 G | DC voltage or current range or field select | DC voltage or current range or field select | 115 VAC or specify | |
| APD HV-DC | DC voltage input range (field changeable) | DC voltage or current range (field changeable) | 85-265 VAC or 60-300 VDC | |
| DC Input Math | Specify Input | Specify Output | Power | |
| APD 4400 |
Specify ranges of A, B, C, and D (A+B+C+D)/4 |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4401 |
Specify ranges of A, B, and C (A+B+C)/3 |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4402 |
Specify ranges of A and B (A+B)/2 |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4403 |
Specify ranges of A, B, C, and D (A+B+C-D)/3 |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4404 |
Specify ranges of A, B, C, and D (A+B-C-D)/2 |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4405 |
Specify ranges of A, B, C, and D A-B-C-D |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4406 |
Specify ranges of A, B, and C (A+B-C)/2 |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4407 |
Specify ranges of A, B, and C A-B-C |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4408 |
Specify ranges of A and B A-B |
DC voltage or current range | 85-265 VAC or 60-300 VDC | |
| APD 4440 | DC range | DC voltage or current range | 115 VAC or specify | |
| Thermocouple | Specify Input | Specify Output | Power | |
| API 1200 G | T/C type, °F or °C range |
Alarm type: choose HI or LO Alarm action: normal (factory set) | 115 VAC or specify | |
| API 1220 G | T/C type, °F or °C range |
Alarm type:
H/L, H/H, L/L, L/H specify or internal jumper select Alarm action: normal (factory set) Setpoints: specify or field adjust |
115 VAC or specify | |
| API 4130 G L | T/C type, °F or °C range | DC voltage or current range | 115 VAC or specify | |
| RTD | Specify Input | Specify Output | Power | |
| API 1400 G | RTD type, °F or °C range |
Alarm type:
HI or LO (factory set) Alarm action: normal (factory set) Setpoint & deadband: specify or field adjust |
115 VAC or specify | |
| API 1420 G | RTD type, °F or °C range |
Alarm type:
H/L, H/H, L/L, L/H specify or internal jumper select Alarm action: normal (factory set) Setpoints: specify or field adjust |
115 VAC or specify | |
| APD 1400 | RTD type, °F or °C range | Alarm type:
HI/LO, norm/rev (factory set) Latching: none, push to reset, power off reset Setpoint & deadband: specify or field adjust |
85-265 VAC or 60-300 VDC | |
| APD 1400 D | RTD type, °F or °C range | Alarm type:
HI/LO, norm/rev (factory set) Latching: none, push to reset, power off reset Setpoint & deadband: specify or field adjust |
9-30 VDC or 10-32 VAC |
|
| APD 1420 | RTD type, °F or °C range | Alarm type:
H/L, H/H, L/L, L/H specify or internal jumper select Alarm action: norm/rev (factory set) Setpoints: specify or field adjust |
85-265 VAC or 60-300 VDC | |
| APD 1420 D | RTD type, °F or °C range | Alarm type:
H/L, H/H, L/L, L/H specify or internal jumper select Alarm action: norm/rev (factory set) Setpoints: specify or field adjust |
9-30 VDC or 10-32 VAC |
|
| API 4001 G L | RTD type, °F or °C range | DC voltage or current range | 115 VAC or specify | |
| DC to Frequency | Specify Input | Specify Output | Power | |
| API 7500 G | DC voltage or current range | 0 to __Hz or field select | 115 VAC or specify | |
| API 7500 G M02 | DC voltage or current range | 0 to __Hz or field select | 115 VAC or specify | |
| API 7500 G SS | DC voltage or current range | 0 to __Hz or field select | 115 VAC or specify | |
| API 7500 G SS M02 | DC voltage or current range | 0 to __Hz or field select | 115 VAC or specify | |
| Frequency Input | Specify Input | Specify Output | Power | |
| API 1700 G | 0 to __Hz |
Alarm type:
HI/LO, norm/rev (factory set) Latching: none, push to reset, power off reset Setpoint & deadband: specify or field adjust |
115 VAC or specify | |
| API 7010 G | 0 to __Hz | DC voltage or current range | 115 VAC or specify | |
| API 7580 G | 0 to __Hz or field select | DC voltage or current range or field select | 115 VAC or specify | |
| APD 7580 | 0 to __Hz or field select | DC voltage or current range or field select | 85-265 VAC or 60-300 VDC | |
| APD 7580 D | 0 to __Hz or field select | DC voltage or current range or field select | 9-30 VDC or 10-32 VAC |
|
| AC Input | Specify Input | Specify Output | Power | |
| API 1600 G | AC voltage or current range |
Alarm type:
HI or LO (factory set) Alarm action: normal (factory set) Setpoint & deadband: specify or field adjust |
115 VAC or specify | |
| API 1620 G | AC voltage or current range |
Alarm type:
H/L, H/H, L/L, L/H specify or internal jumper select Alarm action: normal (factory set) Setpoints: specify or field adjust |
115 VAC or specify | |
| API 6010 G | AC voltage or current range | DC voltage or current range | 115 VAC or specify | |
| API 6380 G | AC voltage or current range or field select | DC voltage or current range or field select | 115 VAC or specify | |
| API 6380 G S | AC voltage or current range or field select | DC voltage or current range or field select | 115 VAC or specify | |
| Potentiometer | Specify Input | Specify Output | Power | |
| API 4003 G I | Specify but will work with any 0-100 Ω to 0-1 MΩ pot. | DC voltage or current range | 115 VAC or specify | |
| API 4008 G | Any 0-100 Ω to 0-1 MΩ pot. Field select | DC voltage or current range or field select | 115 VAC or specify | |
| APD 4008 G | Any 0-100 Ω to 0-1 MΩ pot. Offset allowed. Field select | DC voltage or current range or field select | 85-265 VAC or 60-300 VDC | |
| APD 4008 G D | Any 0-100 Ω to 0-1 MΩ pot. Offset allowed. Field select | DC voltage or current range or field select | 9-30 VDC or 10-32 VAC |
|
| Strain Gauge | Specify Input | Specify Output | Power | |
| API 4051 G | Excitation voltage, sensor mV/V rating | DC voltage or current range | 115 VAC or specify | |
| API 4058 G | Excitation voltage, sensor mV/V rating or field select | DC voltage or current range or field select | 115 VAC or specify | |
| API 4059 G | Excitation voltage, sensor mV/V rating or field select | DC voltage or current range or field select | 115 VAC or specify | |
| APD 4059 | Excitation voltage, sensor mV/V rating or field select | DC voltage or current range or field select | 115 VAC or specify | |
| APD 4059 D | Excitation voltage, sensor mV/V rating or field select | DC voltage or current range or field select | 115 VAC or specify | |
| Valve Position | Specify Input | Specify Output | Power | |
| API 3200 G |
Control input: DC volts or current Feedback: potentiometer, full range 0-100 Ω to 0-100 kΩ |
Relay setpoint & deadband field configured | 115 VAC or specify | |
| API 3200 G M01 |
Control input: DC volts Feedback: 1-5 VDC or specify |
Relay setpoint & deadband field configured | 115 VAC or specify | |
| API 3200 G M03 |
Control input: DC volts or current Feedback: potentiometer using <100% of its range |
Relay setpoint & deadband field configured | 115 VAC or specify | |
| API 3200 G M420 |
Control input: DC current Feedback: 4-20 mA |
Relay setpoint & deadband field configured | 115 VAC or specify | |